American Dryer Corp D-40 Installation, Before YOU Start Check Local Codes and Permits

Page 55

BEFORE YOU START!

CHECK LOCAL CODES AND PERMITS

Call your local water company or the proper municipal authority for information regarding local codes.

IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the plumbing installation is adequate and conforms to local, state, and federal regulations or codes.

IMPORTANT: It is the installation or owners responsibility to see that the necessary or required water, water pressure, pipe size, or connections are provided. Manufacturer assumes no responsibility if the fire suppression system (F.S.S.) is not connected, installed, or maintained properly.

INSTALLATION

1.Requirements

The connection point to the electric water solenoid valve is a 1/2” M.P.T., the FSS MUST BE supplied with a minimum water pipe size of 1/2-inch and be provided with 40 PSI +/- 20 PSI (2.75 bars +/- 1.37 bars) of pressure. For use of optional manual bypass, a second source with the same piping and pressure requirements is required.

Flexible 1/2 feeds must be provided to avoid damage to electric water solenoid valve by vibration.

IMPORTANT: Flexible supply line/coupling MUST BE used. Solenoid valve failure due to hard plumbing connections WILL void warranty.

If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/ freezing temperatures, provisions must be made to protect these water lines from freezing.

WARNING: If the water in the supply line or water solenoid valve freezes, the F.S.S. will be

INOPERATIVE!!

51

Image 55
Contents Installation Manual Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Routine Maintenance Receiving and Handling Important InformationExplosion could Result Safety PrecautionsStandards Specifications SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. C Important Venting Reminders Electrical Requirements Electrical InformationMust be Provided SINGLE-PHASE 1Ø Electrical Connection Leads Important a Circuit Servicing Each Dryer Must be Provided Important a Circuit Servicing Each Dryer Must be Provided 40 GAS Steam GAS Information Type of GAS Page Page Steam Information Operating Steam PressurePage Compressed AIR Pressure AIR Supply Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP GAS Models only Preoperational TestsCoin Models Preoperational InstructionsPage OPL Models Page Service SERVICE/PARTS InformationParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Cleaning Routine MaintenanceSuggested Cleaning Schedule Lubrication AdjustmentsLint Drawer Removal Data Label Data Label InformationSerial Number TIM ING Legend Reversing Timer SPIN/DWELL AdjustmentsProcedure for Functional Check Replacement Components Page F.E. Fire Suppression System F.S.S S. In ActionBefore YOU Start Check Local Codes and Permits InstallationWater Connections Optional Manual Bypass Electrical Requirements System ResetParts Break Down Comp x 3/8 M.P.T. Brass Connector 822752 ADC 113370 1 03/25/02-25

D-40 specifications

American Dryer Corp has long been recognized as a leader in the manufacturing of high-efficiency commercial dryers, and the D-40 model is a prime example of their commitment to delivering quality, performance, and technological advancements. The D-40 is designed to meet the rigorous demands of laundromats, hotels, and other commercial laundry facilities, offering a perfect balance of power and efficiency.

One of the main features of the D-40 is its robust construction. Built with high-quality materials, this dryer ensures durability and longevity even in high-volume operations. The D-40 is equipped with a large capacity tumbler that can accommodate significant loads, making it an ideal choice for businesses that require efficient drying solutions.

The dryer utilizes a state-of-the-art microprocessor control system, allowing users to program multiple drying cycles tailored to specific fabric types or customer preferences. This technology enables precise drying times and temperatures, which helps to prevent damage to garments while maximizing efficiency. The control panel is user-friendly, featuring clear displays and intuitive navigation, ensuring that operators can quickly set up and adjust cycles as needed.

In terms of energy efficiency, the D-40 is engineered with advanced drying technologies that reduce utility costs. Its high-performance gas burners and optimized airflow design allow for rapid heat distribution, which significantly shortens drying times. The dryer also features a reliable heat exchanger system that ensures consistent heat output while minimizing energy consumption.

Another noteworthy characteristic of the D-40 is its sound-dampening design. The dryer is equipped with noise-reduction technology, allowing it to operate quietly, which is particularly beneficial in environments where noise may disrupt customers or staff.

Safety features are also of paramount importance in the D-40’s design. It includes a protective door interlock system that ensures the dryer cannot operate when the door is open, reducing the risk of accidents. Moreover, the D-40 has been designed with easy access for maintenance, making it simpler for technicians to perform routine checks and repairs.

In conclusion, the American Dryer Corp D-40 stands out in the competitive landscape of commercial dryers by combining high-capacity performance with energy efficiency, advanced technology, and a commitment to safety and durability. Its innovative features make it an ideal choice for businesses looking to optimize their laundry operations.