3.Piping Connections

ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance BTUs being supplied.

The dryer is provided with a 1/2” N.P.T. inlet pipe connection extending out the back area of the burner box. The minimum pipe size (supply line) to the dryer is 1/2” N.P.T. For ease in servicing, the gas supply line of each dryer must have its own shutoff valve.

The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc. Specific information regarding supply line size should be determined by the gas supplier.

NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in erratic operation of the burner ignition system.

26

Image 30
Contents Installation Manual Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Routine Maintenance Important Information Receiving and HandlingSafety Precautions Explosion could ResultStandards Specifications SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Vertical Venting Multiple Dryer Common Venting Illus. C Important Venting Reminders Electrical Information Electrical RequirementsMust be Provided SINGLE-PHASE 1Ø Electrical Connection Leads Important a Circuit Servicing Each Dryer Must be Provided Important a Circuit Servicing Each Dryer Must be Provided 40 GAS Steam GAS Information Type of GAS Page Page Operating Steam Pressure Steam InformationPage Compressed AIR Pressure AIR Supply Page Steam Damper Air Piston Flow Control Operation Adjustment Preparation for OPERATION/START-UP Preoperational Tests GAS Models onlyPreoperational Instructions Coin ModelsPage OPL Models Page SERVICE/PARTS Information ServiceParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningSuggested Cleaning Schedule Adjustments LubricationLint Drawer Removal Data Label Information Data LabelSerial Number Reversing Timer SPIN/DWELL Adjustments TIM ING LegendProcedure for Functional Check Replacement Components Page S. In Action F.E. Fire Suppression System F.S.SInstallation Before YOU Start Check Local Codes and PermitsWater Connections Optional Manual Bypass System Reset Electrical RequirementsParts Break Down Comp x 3/8 M.P.T. Brass Connector 822752 ADC 113370 1 03/25/02-25

D-40 specifications

American Dryer Corp has long been recognized as a leader in the manufacturing of high-efficiency commercial dryers, and the D-40 model is a prime example of their commitment to delivering quality, performance, and technological advancements. The D-40 is designed to meet the rigorous demands of laundromats, hotels, and other commercial laundry facilities, offering a perfect balance of power and efficiency.

One of the main features of the D-40 is its robust construction. Built with high-quality materials, this dryer ensures durability and longevity even in high-volume operations. The D-40 is equipped with a large capacity tumbler that can accommodate significant loads, making it an ideal choice for businesses that require efficient drying solutions.

The dryer utilizes a state-of-the-art microprocessor control system, allowing users to program multiple drying cycles tailored to specific fabric types or customer preferences. This technology enables precise drying times and temperatures, which helps to prevent damage to garments while maximizing efficiency. The control panel is user-friendly, featuring clear displays and intuitive navigation, ensuring that operators can quickly set up and adjust cycles as needed.

In terms of energy efficiency, the D-40 is engineered with advanced drying technologies that reduce utility costs. Its high-performance gas burners and optimized airflow design allow for rapid heat distribution, which significantly shortens drying times. The dryer also features a reliable heat exchanger system that ensures consistent heat output while minimizing energy consumption.

Another noteworthy characteristic of the D-40 is its sound-dampening design. The dryer is equipped with noise-reduction technology, allowing it to operate quietly, which is particularly beneficial in environments where noise may disrupt customers or staff.

Safety features are also of paramount importance in the D-40’s design. It includes a protective door interlock system that ensures the dryer cannot operate when the door is open, reducing the risk of accidents. Moreover, the D-40 has been designed with easy access for maintenance, making it simpler for technicians to perform routine checks and repairs.

In conclusion, the American Dryer Corp D-40 stands out in the competitive landscape of commercial dryers by combining high-capacity performance with energy efficiency, advanced technology, and a commitment to safety and durability. Its innovative features make it an ideal choice for businesses looking to optimize their laundry operations.