A. SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

95 lbs.

 

43.1 kg

BASKET (TUMBLER) DIAMETER

42"

 

106.7 cm

BASKET (TUMBLER) DEPTH

29-1/4"

 

74.3 cm

BASKET (TUMBLER) MOTOR

1/2 HP

 

0.373 kw

BLOWER MOTOR

3 HP

 

2.238 kw

DOOR OPENING (DIAMETER)

30-3/4"

 

78.1 cm

BASKET (TUMBLER) VOLUME

23.5 cu. ft.

 

0.67cu. m.

DRYERS PER 20'/40' CONTAINER

 

10/20

 

 

 

 

 

DRYERS PER 45'/48' TRUCK

 

24/24

 

 

 

 

 

 

VOLTAGE AVAILABLE

208-460v

3ø 3, 4w 50/60 Hz

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

878 lbs.

 

453.6 kg

 

 

 

 

 

GAS

APPROX. WEIGHT (CRATED)

1,000 lbs.

 

544.3 kg

 

 

 

 

HEAT INPUT

350,000 btu/hr

 

88,200 kcal/hr

 

 

 

 

 

 

 

 

AIRFLOW

2,700 cfm

 

76.5 cmm

 

 

 

 

 

 

INLET PIPE CONNECTION*

 

1" N.P.T.

 

 

 

 

 

 

COMPRESSED AIR VOLUME

4 cfh

 

0.12 cmh

 

COMPRESSED AIR CONNECTION

 

1/8" F.P.T.

 

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

*Size of piping varies with installation conditions.

IMPORTANT: Dryer must be supplied with clean, dry, and regulated air pressure at 80 PSI ± 10 PSI (5.51 bars ± 0.68 bars).

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents ML-96D Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Page Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Create a Potential Fire HazardAnywhere Downstream of Dryer Page Page Electrical Information G 9 6 D Electrical Connections GAS Information BTU Page Preparation for OPERATION/START-UP Preoperational Tests Operating Instructions Basket CoatingShut Down Instructions Service SERVICE/PARTS InformationParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationProcedure for Functional Check Replacement Components Page Data LABEL/LOCATION Information Data LabelSerial Number Manual Reset HI-LIMIT Instructions For Phase 6 ModelsADC 02/16/00-10 12/08/00-10 03/09/01-25