3)Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column (W.C.) pressure is correct and consistent.
NOTE: Water column pressure requirements (measured at the gas valve pressure tap):
Natural Gas | 3.5 inches (8.7 mb) water column. |
Liquid Propane (L.P.) Gas .... | 10.5 inches (26.1 mb) water column. |
IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
b.Microprocessor Controller (Computer) Dryer Models
1)Spin and stop times are not adjustable in the Automatic Mode and have been preprogrammed into the microprocessor controller (computer) for a 3 minute forward and 2 minute reverse spin time and a
2)Spin and stop times are adjustable in the Manual (timed) Mode.
BASKET COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material with a solution of water and non flammable mild detergent and tumbling them in the basket (tumbler) to remove this coating.
J. OPERATING INSTRUCTIONS
NOTE: Before attempting to start the dryer make sure the main door is closed and the lint drawer is securely in place.
1.To start the dryer:
a. Microprocessor Controller (Computer) Dryer Models
1)Display will read "READY" (meaning no cycle in progress).
2)Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., key "E"). Dryer will start to rotate.
3)Light emitting diode (L.E.D.) display will now toggle "Drying" "Manual" "Cycle E" "30 Min" "Remain" meaning the dryer is in the drying cycle and count down in minutes.
NOTE: Pressing keyboard (touch pad) key "A," "B," "C," "D," and "F" will also start the dryer. The six (6) preprogrammed drying cycles ("A" through "F") have been stored in the microprocessor controller's (computer's) memory. Refer to the Computer Programming Manual supplied with dryer for more specific operating information.
27