American Dryer Corp ML-96D installation manual Btu

Page 27

2.Technical Gas Data a. Gas Specifications

 

 

 

TYPE OF GAS

 

 

 

 

 

 

 

 

Natural

 

Liquid Propane

 

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

 

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

 

Inline Pressure

6.0 - 12.0 inches W.C.

 

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Measured at gas valve pressure tap when the gas valve is on.

b.Gas Connections

Inlet connection ----------- 1-inch N.P.T.

Inlet supply size ----------- 1-inch N.P.T. (minimum)

Heat input (per dryer) ---- 350,000 BTU/hr input - 88,200 kcal/hr

1)Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

 

 

TYPE OF GAS

 

L.P.

 

 

 

 

 

 

 

 

 

Conversion

MODEL

BTU

kcal/hr

 

Natural

 

Liquid Propane

 

 

Kit

Per Hour

 

 

Part

 

 

Part

NUMBER

Rating

Qty.

D.M.S.*

Qty.

D.M.S.*

Part Number

Rating

Number

Number

 

 

ML-96D

350,000

88,200

3

#10

140836

3

#33

140855

882199

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

*Drill Material Size (D.M.S.) equivalents are as follows:

Natural Gas ..................... # 10 = 0.1935" (4.9149 mm). Liquid Propane Gas ...... # 33 = 0.1130" (2.8702 mm).

23

Image 27
Contents ML-96D Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications Component Identification Page Location Requirements Installation ProceduresUNPACKING/SETTING UP Page Dryer Enclosure Requirements Fresh AIR Supply Create a Potential Fire Hazard Exhaust RequirementsAnywhere Downstream of Dryer Page Page Electrical Information G 9 6 D Electrical Connections GAS Information BTU Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Operating InstructionsShut Down Instructions SERVICE/PARTS Information ServiceParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Cleaning Routine MaintenanceLubrication AdjustmentsProcedure for Functional Check Replacement Components Page Data Label Data LABEL/LOCATION InformationSerial Number For Phase 6 Models Manual Reset HI-LIMIT InstructionsADC 02/16/00-10 12/08/00-10 03/09/01-25