American Dryer Corp MDG31 manual MDG77 Specifications

Page 10

MDG77 Specifications ______________________________________________________________

MAXIMUM CAPACITY (DRY WEIGHT)

 

75 lb

34.02 kg

TUMBLER DIAMETER

 

37”

93.98 cm

TUMBLER DEPTH

 

 

 

35-1/2”

90.17 cm

TUMBLER VOLUME

 

 

 

22.09 cu ft

625.52 L

TUMBLER/DRIVE MOTOR

 

1 hp

0.75 kW

BLOWER/FAN MOTOR

 

1/2 hp

0.37 kW

DOOR OPENING (DIAMETER)

 

27-3/8”

69.53 cm

DOOR SILL HEIGHT

 

 

 

16”

40.64 cm

WATER CONNECTION

 

3/4”-11.5 NH (North America)

 

 

 

 

 

 

3/4” B.S.P.T. (Outside North America)

DRYERS PER 20’/40’ CONTAINER

 

9 / 20

DRYERS PER 48’/53’ TRUCK

 

25 / 27

 

VOLTAGE AVAILABLE

 

120V 1ø

2w 60 Hz

 

APPROXIMATE NET WEIGHT

 

600 lb

272.16 kg

 

APPROXIMATE SHIPPING WEIGHT

620 lb

281.23 kg

Gas

AIRFLOW

 

 

 

560 cfm

15.86 cmm

HEAT INPUT

 

 

 

110,000 Btu/hr

27,720 kcal/hr

 

 

 

 

 

EXHAUST CONNECTION (DIAMETER)

8”

20.32 cm

 

COMPRESSED AIR CONNECTION

N / A

 

COMPRESSED AIR VOLUME

 

N / A

 

INLET PIPE CONNECTION

 

1/2” M.N.P.T.

 

 

 

 

 

 

1/2” F.B.S.P.T. (CE and Australia Only)

 

VOLTAGE AVAILABLE

 

 

 

Electric

APPROXIMATE NET WEIGHT

 

 

 

APPROXIMATE SHIPPING WEIGHT

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

 

EXHAUST CONNECTION (DIAMETER)

N / A

 

COMPRESSED AIR CONNECTION

 

 

 

COMPRESSED AIR VOLUME

 

 

 

 

 

 

OVEN SIZE

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

VOLTAGE AVAILABLE

 

 

 

 

APPROXIMATE NET WEIGHT

 

 

 

 

APPROXIMATE SHIPPING WEIGHT

 

 

Steam

AIRFLOW

 

 

 

 

 

STEAM CONSUMPTION

 

 

 

 

 

 

 

 

OPERATING STEAM PRESSURE

N / A

 

EXHAUST CONNECTION (DIAMETER)

 

 

 

 

COMPRESSED AIR CONNECTION

 

 

 

COMPRESSED AIR VOLUME

 

 

 

 

BOILER HORSEPOWER (NORMAL LOAD)

 

 

 

SUPPLY CONNECTION

 

 

 

 

RETURN CONNECTION

 

 

 

Shaded areas are stated in metric equivalents

 

 

11/23/05

Note

!The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

10

Maytag Co.

113430 - 9

Image 10
Contents MDG31 / MDG51 / MDG77 Installation/Operator Manual Retain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only MDG31 Specifications MDG31 Specifications MDG51 Specifications MDG51 Specifications MDG77 Specifications MDG77 Specifications Location Requirements Installation ProceduresUnpacking/Setting Up Dryer Enclosure RequirementsExhaust Requirements Fresh Air Supply RequirementsDomestic Type I MDG31, MDG51 Only Horizontal Venting Outside Ductwork ProtectionSingle Dryer Venting Vertical VentingElectrical Information Electrical RequirementsGrounding Electrical Service Specifications Gas Models OnlySingle-Phase 1ø Wiring Connections/Hookup Electrical ConnectionsGas Information CE DryersMDG31 Conversion from Natural Gas to Propane or Butane Gas Converting from One Family Gas to AnotherPiping/Connections Parts Required for ConversionRegulated Gas Valve Non-CE DryersUnregulated Gas Valve Conversion from Propane or Butane Gas to Natural GasGas Pressure Test Procedure Gas Pressure TestingGas Pressure Adjustment Water InformationPreparation for Operation/Start-Up Preoperational TestCoin Models Service/Parts InformationPreoperational Instructions Non-Coin ModelsWarranty Information Routine MaintenanceData Label Information Days After Installation Every 12 Months ThereafterStandard Label CE Label 02/15/08