American Dryer Corp MDG77, MDG31 manual MDG51 Specifications

Page 8

MDG51 Specifications _________________________________________________________________

MAXIMUM CAPACITY (DRY WEIGHT)

 

50 lb

22.68 kg

TUMBLER DIAMETER

 

37”

93.98 cm

TUMBLER DEPTH

 

 

 

25-3/4”

65.41 cm

TUMBLER VOLUME

 

 

 

16.02 cu ft

453.64 L

TUMBLER/DRIVE MOTOR

 

1 hp

0.75 kW

BLOWER/FAN MOTOR

 

1/2 hp

0.37 kW

DOOR OPENING (DIAMETER)

 

27-3/8”

69.55 cm

DOOR SILL HEIGHT

 

 

 

16”

40.64 cm

WATER CONNECTION

 

3/4”-11.5 NH (North America)

 

 

 

 

 

 

3/4” B.S.P.T. (Outside North America)

DRYERS PER 20’/40’ CONTAINER

 

10 / 22

DRYERS PER 48’/53’ TRUCK

 

28 / 30

 

VOLTAGE AVAILABLE

 

120V 1ø

2w 60 Hz

 

APPROXIMATE NET WEIGHT

 

545 lb

247.21 kg

 

APPROXIMATE SHIPPING WEIGHT

565 lb

256.28 kg

Gas

AIRFLOW

 

 

 

525 cfm

14.87 cmm

HEAT INPUT

 

 

 

90,000 Btu/hr

22,680 kcal/hr

 

 

 

 

 

EXHAUST CONNECTION (DIAMETER)

8”

20.32 cm

 

COMPRESSED AIR CONNECTION

N / A

 

COMPRESSED AIR VOLUME

 

N / A

 

INLET PIPE CONNECTION

 

1/2” M.N.P.T.

 

 

 

 

 

 

1/2” F.B.S.P.T. (CE and Australia Only)

 

VOLTAGE AVAILABLE

 

 

 

Electric

APPROXIMATE NET WEIGHT

 

 

 

APPROXIMATE SHIPPING WEIGHT

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

 

EXHAUST CONNECTION (DIAMETER)

N / A

 

COMPRESSED AIR CONNECTION

 

 

 

COMPRESSED AIR VOLUME

 

 

 

 

 

 

OVEN SIZE

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

VOLTAGE AVAILABLE

 

 

 

 

APPROXIMATE NET WEIGHT

 

 

 

 

APPROXIMATE SHIPPING WEIGHT

 

 

Steam

AIRFLOW

 

 

 

 

 

STEAM CONSUMPTION

 

 

 

 

 

 

 

 

OPERATING STEAM PRESSURE

N / A

 

EXHAUST CONNECTION (DIAMETER)

 

 

 

 

COMPRESSED AIR CONNECTION

 

 

 

COMPRESSED AIR VOLUME

 

 

 

 

BOILER HORSEPOWER (NORMAL LOAD)

 

 

 

SUPPLY CONNECTION

 

 

 

 

RETURN CONNECTION

 

 

 

Shaded areas are stated in metric equivalents

 

 

11/23/05

Note

!The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

8

Maytag Co.

113430 - 9

Image 8
Contents MDG31 / MDG51 / MDG77 Installation/Operator Manual Retain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only MDG31 Specifications MDG31 Specifications MDG51 Specifications MDG51 Specifications MDG77 Specifications MDG77 Specifications Installation Procedures Unpacking/Setting UpLocation Requirements Dryer Enclosure RequirementsDomestic Type I MDG31, MDG51 Only Fresh Air Supply RequirementsExhaust Requirements Outside Ductwork Protection Single Dryer VentingHorizontal Venting Vertical VentingElectrical Information Electrical RequirementsElectrical Service Specifications Gas Models Only Single-Phase 1ø Wiring Connections/HookupGrounding Electrical ConnectionsGas Information CE DryersMDG31 Converting from One Family Gas to Another Piping/ConnectionsConversion from Natural Gas to Propane or Butane Gas Parts Required for ConversionNon-CE Dryers Unregulated Gas ValveRegulated Gas Valve Conversion from Propane or Butane Gas to Natural GasGas Pressure Testing Gas Pressure AdjustmentGas Pressure Test Procedure Water InformationPreparation for Operation/Start-Up Preoperational TestService/Parts Information Preoperational InstructionsCoin Models Non-Coin ModelsWarranty Information Routine MaintenanceStandard Label CE Label Days After Installation Every 12 Months ThereafterData Label Information 02/15/08