Heat Input/Gas Consumption/Orifice (Injector) Data (For Non-CE [European] Models Only)

Gas Specifications for Non-CE Approved Dryers**

Model

Gas

Nominal

Supply

Gross

Orifice Size

Orifice

Burner

Heating Value

Pressure

Heat Input

 

 

(Injector)

Pressure

 

Type

 

 

 

 

 

 

Quantity

 

 

Btu/ft3

in WC

Btu/hr

kW

DMS

mm

in WC

 

 

MDG31

Natural

1,000

7.0-13.0

55,000

16.12

20

4.089

1

3.0

*Liquid Propane

2,500

11.0

55,000

16.12

44

2.184

1

10.0

 

MDG51

Natural

1,000

7.0-13.0

90,000

26.38

29

3.454

2

3.0

*Liquid Propane

2,500

11.0

90,000

26.38

47

2.994

2

10.0

 

MDG77

Natural

1,000

7.0-13.0

110,000

32.24

22

3.988

2

3.0

*Liquid Propane

2,500

11.0

110,000

32.24

44

2.184

2

10.0

 

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)

Gas Specifications for CE Approved Dryers**

 

Gas

 

 

Nominal

Supply

Gross

Fuel

Orifice Size

Orifice

Burner

Model

 

 

Heating Value

Pressure

Heat Input

(Injector)

Pressure

Type

 

 

Consumption

 

 

 

 

 

 

 

 

 

 

 

Quantity

 

 

 

 

 

 

Btu/ft3

mb

Btu/hr

kW

 

 

DMS

mm

mb

 

Natural (I

/I

2E

)

1,000

15-30

55,000

16.12

1.557 M3/H

22

3.988

1

6.9

 

 

2H

 

 

 

 

 

 

 

 

 

 

 

 

Natural (I

)

 

 

830

20-35

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

 

 

2L

 

 

 

 

 

 

 

 

 

 

 

 

MDG31

Natural (I2E L L)

 

830

15-30

55,000

16.12

1.876

M3/H

22

3.988

1

9.5

*Natural (I2E+)

 

1,000

20

55,000

16.12

1.557 M3/H

31

3.048

1

 

 

 

 

830

25

55,000

16.12

1.876 M3/H

31

3.048

1

 

 

 

 

 

 

*Butane (I3+)

 

 

3,175

28-30

55,000

16.12

1.162 kg/H

48

1.930

1

 

*Propane (I3+)

 

2,500

37

55,000

16.12

1.162 kg/H

48

1.930

1

 

Butane (I3B/P)

 

3,175

28-30/50

55,000

16.12

1.162

kg/H

44

2.184

1

18.1

 

Propane (I3P)

 

2,500

28-30/50

55,000

16.12

1.162

kg/H

44

2.184

1

24.9

 

Natural (I

/I

2E

)

1,000

15-30

90,000

26.38

2.549

M3/H

29

3.454

2

7.2

 

 

2H

 

 

 

 

 

 

 

 

 

 

 

 

Natural (I2L)

 

 

830

20-35

90,000

26.38

3.071

M3/H

29

3.454

2

8.9

MDG51

Natural (I2E L L)

 

830

15-30

90,000

26.38

3.071 M3/H

29

3.454

2

8.9

*Natural (I2E+)

 

1,000

20

90,000

26.38

2.549

M3/H

35

2.794

2

 

 

 

 

830

25

90,000

26.38

3.071

M3/H

35

2.794

2

 

 

 

 

 

 

*Butane (I3+)

 

 

3,175

28-30

90,000

26.38

1.901 kg/H

50

1.778

2

 

*Propane (I3+)

 

2,500

37

90,000

26.38

1.901 kg/H

50

1.778

2

 

Butane (I3B/P)

 

3,175

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

18.1

 

Propane (I3P)

 

2,500

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

24.9

 

Natural (I

/I

2E

)

1,000

15-30

110,000

32.24

3.115 M3/H

22

3.988

2

6.9

 

 

2H

 

 

 

 

 

 

 

 

 

 

 

 

Natural (I2L)

 

 

830

20-35

110,000

32.24

3.753

M3/H

22

3.988

2

9.5

MDG77

Natural (I2E L L)

 

830

15-30

110,000

32.24

3.753 M3/H

22

3.988

2

9.5

*Natural (I2E+)

 

1,000

20

110,000

32.24

3.115 M3/H

31

3.048

2

 

 

 

 

830

25

110,000

32.24

3.753

M3/H

31

3.048

2

 

 

 

 

 

 

*Butane (I3+)

 

 

3,175

28-30

110,000

32.24

2.324 kg/H

48

1.930

2

 

*Propane (I3+)

 

2,500

37

110,000

32.24

2.324 kg/H

48

1.930

2

 

Butane (I3B/P)

 

3,175

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

18.1

 

Propane (I3P)

 

2,500

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

24.9

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

18

Maytag Co.

113430 - 9

Image 18
Contents MDG31 / MDG51 / MDG77 Installation/Operator Manual Retain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only MDG31 Specifications MDG31 Specifications MDG51 Specifications MDG51 Specifications MDG77 Specifications MDG77 Specifications Location Requirements Installation ProceduresUnpacking/Setting Up Dryer Enclosure RequirementsFresh Air Supply Requirements Exhaust RequirementsDomestic Type I MDG31, MDG51 Only Horizontal Venting Outside Ductwork ProtectionSingle Dryer Venting Vertical VentingElectrical Information Electrical RequirementsGrounding Electrical Service Specifications Gas Models OnlySingle-Phase 1ø Wiring Connections/Hookup Electrical ConnectionsGas Information CE DryersMDG31 Conversion from Natural Gas to Propane or Butane Gas Converting from One Family Gas to AnotherPiping/Connections Parts Required for ConversionRegulated Gas Valve Non-CE DryersUnregulated Gas Valve Conversion from Propane or Butane Gas to Natural GasGas Pressure Test Procedure Gas Pressure TestingGas Pressure Adjustment Water InformationPreparation for Operation/Start-Up Preoperational TestCoin Models Service/Parts InformationPreoperational Instructions Non-Coin ModelsWarranty Information Routine MaintenanceDays After Installation Every 12 Months Thereafter Data Label InformationStandard Label CE Label 02/15/08