Piping/Connections

MDG31

MDG51

MDG77

 

 

 

1/2”

1/2”

1/2”

 

 

 

CE dryer connections will be B.S.P.T., all others will be N.P.T.

There should be a minimum 6-inch (15.24 cm) clearance between the back guard and the first bend in the gas piping for ease of servicing. It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servicing.

The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc. Specific information regarding supply line size should be determined by the gas supplier.

Note

!Undersized gas supply piping can create a low or inconsistent pressure, which will result in erratic

operation of the burner ignition system.

TYPICAL NATURAL GAS INSTALLATION

TYPICAL L.P. GAS INSTALLATION

Consistent gas pressure is essential at all gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 13.0 in wc (32.34 mb) pressure.

A plugged tap, accessible for a pressure gauge connection, must be installed in the main gas supply line immediately upstream of the dryers.

Important

!Pipe joint compounds that resist the action of natural, L.P., and butane gases must be used.

Test all connections for leaks by brushing on a soapy water solution (liquid detergent works well).

Warning

!Never test for leaks with a flame!!!

Converting from One Family

of Gas to Another ______________________

Warning (CE Dryers)

!This appliance must only be operated with the gas type indicated on the dryer’s data plate. If the

appliance is converted (gas type changed), a data plate amendment must be obtained from Maytag (dryer’s serial number is required to purchase a conversion kit).

Important

!Any burner changes or conversions must be made by a qualified professional.

The dryers manufactured for Belgium, Luxemburg, Greece, Estonia, Slovak Republic, Iceland, Malta, Poland and Cyprus cannot be converted from one family of gas to another.

Conversion from Natural Gas to Propane or Butane Gas

The following conversion allows the dryer to be operated with either propane, butane, or LPG. The use of gas valve kit (P/N 140414) disables the internal regulator of the gas valve. Therefore, the gas supply is ungoverned and an external regulator must be provided at the source of the supply (example L.P. tank) or the gas supply line to the dryer. The type of L.P. kit supplied will depend on the country the dryer is installed in.

Parts Required for Conversion:

Description

P/N

Qty

Unregulated Gas Conversion Kit**

140414

***

OR

 

 

Regulated L.P. Gas Conversion Kit****

140416

***

Burner Orifice (Injector)

*

***

L.P. Conversion Label

114515

1

*Refer to page 18 for orifice (injector) size.

**Required for unregulated propane or butane only.

***MDG31 will require 1; MDG51 and MDG77 will require 2.

****Required for regulated LPG or propane only.

Instructions

Disconnect electrical power to the dryer.

Close all shutoff valves in dryer’s gas supply line.

Important

!The MDG51 and MDG77 will require that the following procedures be performed on both

burner assemblies.

Open the panel located just below the loading door.

113430 - 9

Telephone: (641) 787-7000

19

Image 19
Contents MDG31 / MDG51 / MDG77 Installation/Operator Manual Retain This Manual in a Safe Place for Future Reference Table of Contents What To Do If You Smell Gas Safety PrecautionsCE only MDG31 Specifications MDG31 Specifications MDG51 Specifications MDG51 Specifications MDG77 Specifications MDG77 Specifications Dryer Enclosure Requirements Installation ProceduresUnpacking/Setting Up Location RequirementsExhaust Requirements Fresh Air Supply RequirementsDomestic Type I MDG31, MDG51 Only Vertical Venting Outside Ductwork ProtectionSingle Dryer Venting Horizontal VentingElectrical Requirements Electrical InformationElectrical Connections Electrical Service Specifications Gas Models OnlySingle-Phase 1ø Wiring Connections/Hookup GroundingCE Dryers Gas InformationMDG31 Parts Required for Conversion Converting from One Family Gas to AnotherPiping/Connections Conversion from Natural Gas to Propane or Butane GasConversion from Propane or Butane Gas to Natural Gas Non-CE DryersUnregulated Gas Valve Regulated Gas ValveWater Information Gas Pressure TestingGas Pressure Adjustment Gas Pressure Test ProcedurePreoperational Test Preparation for Operation/Start-UpNon-Coin Models Service/Parts InformationPreoperational Instructions Coin ModelsRoutine Maintenance Warranty InformationData Label Information Days After Installation Every 12 Months ThereafterStandard Label CE Label 02/15/08