American Dryer Corp ML-55HS SPECIFICATIONS/COMPONENT Identification, Specifications

Page 10

SECTION II

SPECIFICATIONS/COMPONENT IDENTIFICATION

A. SPECIFICATIONS

 

 

 

 

 

WITHOUT HEAT RECLAIMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM CAPACITY (DRY WEIGHT)

 

 

55 lbs

 

 

 

25 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BASKET (TUMBLER) DIAMETER

 

37"

 

 

 

94 cm

 

 

 

 

 

 

WITH

 

 

 

 

 

BASKET (TUMBLER) DEPTH

 

 

30"

 

 

76.2 cm

 

 

 

 

HEAT RECLAIMER

 

 

 

BASKET (TUMBLER) VOLUME

18.67 cu. ft.

0.528 cu. m.

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR (HORSEPOWER)

 

 

 

3/4 HP

 

 

0.56 kw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOOR OPENING

 

 

31-3/8"

 

 

79.7 cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

 

 

585 lbs

 

 

265 kg

 

 

630 lbs

 

 

 

 

 

286 kg

 

 

 

APPROX. WEIGHT (CRATED)

 

 

 

645 lbs

 

 

293 kg

 

 

690 lbs

 

 

 

 

 

313 kg

 

 

 

 

 

 

 

 

 

 

 

 

GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

600 cfm

 

 

17 cmm

375 cfm

 

 

 

 

10.6 cmm

 

 

 

HEAT INPUT

 

 

 

 

160,000 btu/hr

40,320 kcal/hr

140,000 btu/hr

 

 

35,280 kcal/hr

 

GAS INLET

 

 

 

 

 

 

 

1/2"

 

 

 

 

 

 

 

 

 

1/2"

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

 

 

 

 

 

 

 

 

120 VOLTS OR 230 VOLTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

600 cfm

 

 

 

 

 

 

 

 

 

17 cmm

 

 

 

 

 

 

OVEN SIZE

 

 

 

 

 

 

 

 

APPLIED VOLTAGE/PHASE

 

 

 

 

 

 

 

 

Kw

 

btu/hr

 

kcal/hr

AMPS

 

208/1ø

240/1ø

 

208/3ø

240/3ø

380/3ø

 

416/3ø

460/3ø

 

 

 

 

 

 

 

60 Hz

 

50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 Hz

50 Hz

60 Hz

 

50 Hz

 

60 Hz

50 Hz

60 Hz

 

50 Hz

60 Hz

 

50 Hz

60 Hz

50 Hz

60 Hz

 

50 Hz

20

 

68,260

 

17,200

 

 

103

---

90

 

---

 

---

---

---

 

---

---

 

33

 

---

---

---

 

---

24

 

81,910

 

20,640

 

 

---

---

---

 

---

 

70

---

62

 

62

---

 

---

 

---

36

31

 

---

30

 

102,390

 

25,800

 

 

---

---

---

 

---

86

---

75

75

---

 

---

 

---

44

38

 

---

 

 

 

 

 

 

 

 

STEAM*†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

600 cfm

 

 

 

 

 

 

 

 

 

17 cmm

 

 

 

STEAM CONSUMPTION

 

 

BOILER HP

 

 

 

 

OPERATING

 

STEAM

 

STEAM

 

 

 

NORMAL LOAD

 

 

 

STEAM PRESSURE

SUPPLY

 

RETURN

 

 

 

 

 

 

 

 

 

 

 

144.7 lb/hr

 

65.7 kg/hr

 

 

 

4.2

 

 

 

 

125 psi

8.6 bar

 

1"

 

 

 

1"

 

 

Shaded areas are stated in metric equivalents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Specify Air-Operated Steam Damper system or Electromechanical Steam Damper system when ordering.

Air-Operated Steam Damper system must be provided with a clean, dry, regulated 80 psi ± 10 psi (5.52 bars ± 0.68 bars). Air connection is 1/8" N.P.T. Air volume requirement is 0.75 cfh (0.02cmh).

IMPORTANT: Steam dryers must be provided with clean, dry, regulated 80 PSI ± 10 PSI (5.52 bars ± 0.68 bars) air supply.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents ML-55HS Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Electric Service Relay Box Installation Procedures Location RequirementsUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Requirements Exhaust Requirements Create a Potential Fire HazardPage Page Page Electrical Information MLG-55 Gas MLS-55 Steam Page Black White Green Positive Neutral Ground Page Page Page GAS Information Type of GAS Page Steam Information Operating Steam Pressure Page Bars Steam System Operation Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Preoperational Instructions Shut Down Instructions Service SERVICE/PARTS InformationParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningAdjustments LubricationProcedure for Functional Check Replacement Components Page Page Reversing Timer SPIN/DWELL Adjustments Timing LegendData Label Information Data LabelSerial Number Manual Reset HI-LIMIT Instructions P O R TA N TP O RTA N T ADC 113000 9-11/23/05-0