4. Peel paper backing off new keyboard label assembly.
5. Holding the new keyboard label assembly close to the panel, insert the keyboard ribbon through the rectangular slot in the control panel. Align label assembly into position by matching the red viewing window on the label to the rectangular cutout in the panel and gently press into place.
6.Connect keyboard ribbon to the computer.
7.Reestablish power to dryer.
To Replace Microprocessor Temperature Sensor Probe
1. Discontinue power to dryer.
2. Remove lint drawer. Remove two (2) screws securing lint door and remove lint door.
3. Remove microprocessor sensor bracket assembly from dryer.
a. Disconnect sensor bracket harness connector.
b. Loosen the two (2) Phillips head screws securing bracket assembly to dryer and remove bracket from dryer.
NOTE: DO NOT remove screws.
4.Disassemble sensor probe from bracket assembly by removing the top
5.Disconnect the two (2) orange wires from the high heat (225 degree) thermostat, and remove modular bracket connector, wires, and probe from bracket assembly.
6.Install new sensor probe assembly (ADC P/N 880251) by reversing procedure.
7.Reestablish power to the dryer.
NOTE: If, when power is reestablished, the computer display reads "dSFL", check for a loose connection in the wiring.
15