12.Display reads "dSFL". Dryer Sensor Circuit Failure.

A.Check 1/8 amp fuse on computer

B.Faulty microprocessor temperature sensor probe

C.Open circuit in either one of two (2) wires leading from the sensor probe to the computer

1)Connection at sensor bracket assembly connector

2)Connection at computer harness connector

D.Faulty microprocessor (computer) controller

13.Dryer does not start. Display reads "door".

A.Main door is open

B.Lint drawer is open

C.Faulty main door or lint door switch

D.Open circuit in either main door or lint drawer switch harnesses

E.Faulty 24 V transformer

14.There is excessive vibration coming from the basket.

A.Basket is out of adjustment

B.Loose or broken tie rod

C.Failed tumbler support

40

Image 44
Contents AD-170 Retain This Manual In a Safe Place For Future Reference AD-170Page For Your Safety Table of Contents Sail Switch Assembly Safety Precautions Important InformationRoutine Maintenance CleaningAdjustments LubricationInstallation Requirements Enclosure, Air Supply, and Exhaust RequirementsOperational Service Check Procedure Electrical and Gas RequirementsComputer Panel Assembly Description of PartsControl Box DSI Module Gas Models OnlyGas Burner Assembly Drive MotorBlower Motor and Impellor Hz Gas Models Only Blower Motor and Impellor 50Hz, 60Hz Steam & 50Hz GasBasket Tumbler Idler AssemblyTumbler Bearing and Pulley Arrangement Hi-Limit Gas Models Only Main Door SwitchSail Switch Gas Models only Automatic Reset Thermostat Lint Drawer SwitchLint Drawer Steam Damper SystemServicing IntroductionTo Replace Keyboard Label Assembly Computer Controls To Replace ComputerTo Replace Microprocessor Temperature Sensor Probe Page To Replace Gas Valve see burner illustration on To Replace Main Burner OrificesTo Test and Adjust Gas Water Column Pressure To Convert from Natural Gas to L.P. Gas To Replace Burner Tubes To Replace DSI Module Sail Switch Assembly Gas Models Only To Replace Sail Switch To Adjust Sail SwitchTo Replace Main Door Assembly To Install New Main Door GlassTo Replace Front Panel To Replace Main Door Hinge PadPulleys To Replace Tumbler Pulley To Replace Small Idler PulleyTo Replace Large Idler Pulley To Replace Motor PulleyPage Basket Alignment Lateral Side to Side Adjustment To Replace Tumbler Basket or Tumbler Basket SupportImportant Never strike the shaft directly with a hammer To Replace Front Basket Support Pillow Block Bearing To Replace Front Idler Shaft Pillow Block BearingBelts See illustrations in section F Pulleys Belt Tension Adjustment Basket to IdlerTo Replace Rear Idler Shaft Pillow Block Bearing Motors To Replace Drive Motor Belt Tension Adjustment Motor to IdlerTo Replace V-Belts Page Impellor Lint Drawer Assembly To Replace Lint ScreenTo Replace Lint Drawer Switch Computer will not accept key pad entries TroubleshootingNo display on computer Dryer will not start, but computer display indicators are on Drive motor runs, burner is on, but basket will not turnDryer operates, probe sparks, but gas does not flow Dryer operates but is taking too long to dryOverload for impellor fan motor is tripping Dryer is cycling on burner hi-limit safety thermostatThermal overload for drive motor is tripping There is excessive vibration coming from the basket Display reads dSFL. Dryer Sensor Circuit FailureDryer does not start. Display reads door Electrical Trouble Shooting Phase 5 OPL System Diagnostics Diagnostic LED Display Failure CodesLED Display Indicators Page Page LED Display/Codes Cycle StatusLED Display Codes CY FFill Fault Codes Computer Logic and Wiring DiagramPage No Display Condition Page Blower motor does not operate, drive motor runs Door condition Microprocessor reads Dsfl Technical Information Motor Plate High and Low VoltageData Label Contacting American Dryer Corporation ADC Information on the Data LabelUsing a Manometer HOW to USE a ManometerAD-170SE Tool List ADC450400 1- 02/27/98-50