SECTION V |
| |
Servicing | 13 | |
A. Computer Controls | 14 | |
B. Ignition Controls | 16 | |
C. Thermostats | 21 | |
D. Sail Switch Assembly |
| |
| (for Gas Models ONLY) | 22 |
E. Front Panel and Main Door Assemblies | 23 | |
F. Pulleys | 26 | |
G. Basket Assembly | 28 | |
H. Bearings |
| |
| (refer to illustrations in Section F "Pulleys") | 30 |
I. |
| |
| (refer to illustrations in Section F "Pulleys") | 32 |
J. | Motors | 33 |
K. Impellor | 35 | |
L. Lint Drawer Assembly | 35 | |
SECTION VI |
| |
Troubleshooting | 36 | |
1. No display on computer | 36 | |
2. Computer will not accept key pad entries | 36 | |
3. Dryer will not start, but computer display indicators are on | 37 | |
4. Drive motor runs, burner is on, but basket will not turn | 37 | |
5. Drive motor and blower start, computer display heat indicator is on, but there is no heat | 37 | |
6. Dryer operates, probe sparks, but gas does not flow | 38 | |
7. Dryer operates, probe sparks but there is no ignition even though gas is evident | 38 | |
8. Dryer operates but is taking too long to dry | 38 | |
9. Thermal overload for drive motor is tripping | 39 | |
10. Overload for impellor (fan) motor is tripping | 39 | |
11. Dryer is cycling on burner | 39 | |
12. Display reads "dSFL" (Dryer Sensor Circuit Failure) | 40 | |
13. Dryer does not start...display reads "door" | 40 | |
14. There is excessive vibration coming from the basket (tumbler) | 40 | |
SECTION VII |
| |
Electrical Troubleshooting | 41 | |
A. Phase 5 OPL System Diagnostics | 42 | |
B. LED Display Indicators | 43 | |
C. LED Display/Codes | 46 | |
D. Computer Logic and Wiring Diagram | 49 | |
SECTION VIII |
| |
Technical Information | 56 | |
A. Motor Plate (High and Low Voltage) | 56 | |
B. Data Label | 57 | |
C. Using a Manometer | 58 | |
D. | 59 |