D. Gas Burner Assembly
Gas-heated dryers are equipped with a gas burner assembly consisting of four (4) burner tubes, gas valve, spark ignition probe assembly, sail switch, and hi-limit thermostat. The inlet piping enters through the rear of the dryer on the left-hand side (viewing from the front) and runs to the front of the dryer where the gas valve is located.
E. Drive Motor
The T.E.F.C. (totally enclosed, fan-cooled) drive motor is located approximately lower center of the dryer. It sits on an adjustable base so that the motor can be easily adjusted to the left or right, up or down, forward or back- ward. The drive motor is a 3/4 HP motor and operates on 208 to 408 volts, 3Ø, 50/60 Hz.
F. Blower Motor and Impellor
(60 Hz Gas Models Only)
The blower motor is located on the back of the dryer at the lower right-hand corner. The impellor is a backward curved paddle wheel which is directly connected to the shaft of the blower motor. The blower motor is a 3 HP motor and operates on 208 to 460 volts, 3Ø, 50/60 Hz.
G. Blower Motor and Impellor
(50Hz, 60Hz Steam & 50Hz Gas)
The impellor on this design is shaft driven. The blower motor drives the shaft on which the impellor is mounted. This enables the impellor to run at a higher RPM, thereby producing a higher air flow (CFM).
9