American Dryer Corp AD-170 service manual Gas Burner Assembly, Drive Motor

Page 13

D. Gas Burner Assembly

Gas-heated dryers are equipped with a gas burner assembly consisting of four (4) burner tubes, gas valve, spark ignition probe assembly, sail switch, and hi-limit thermostat. The inlet piping enters through the rear of the dryer on the left-hand side (viewing from the front) and runs to the front of the dryer where the gas valve is located.

E. Drive Motor

The T.E.F.C. (totally enclosed, fan-cooled) drive motor is located approximately lower center of the dryer. It sits on an adjustable base so that the motor can be easily adjusted to the left or right, up or down, forward or back- ward. The drive motor is a 3/4 HP motor and operates on 208 to 408 volts, 3Ø, 50/60 Hz.

F. Blower Motor and Impellor

(60 Hz Gas Models Only)

The blower motor is located on the back of the dryer at the lower right-hand corner. The impellor is a backward curved paddle wheel which is directly connected to the shaft of the blower motor. The blower motor is a 3 HP motor and operates on 208 to 460 volts, 3Ø, 50/60 Hz.

G. Blower Motor and Impellor

(50Hz, 60Hz Steam & 50Hz Gas)

The impellor on this design is shaft driven. The blower motor drives the shaft on which the impellor is mounted. This enables the impellor to run at a higher RPM, thereby producing a higher air flow (CFM).

9

Image 13
Contents AD-170 AD-170 Retain This Manual In a Safe Place For Future ReferencePage For Your Safety Table of Contents Sail Switch Assembly Important Information Safety PrecautionsCleaning Routine MaintenanceLubrication AdjustmentsEnclosure, Air Supply, and Exhaust Requirements Installation RequirementsElectrical and Gas Requirements Operational Service Check ProcedureDescription of Parts Computer Panel AssemblyControl Box DSI Module Gas Models OnlyDrive Motor Gas Burner AssemblyBlower Motor and Impellor Hz Gas Models Only Blower Motor and Impellor 50Hz, 60Hz Steam & 50Hz GasTumbler Bearing and Pulley Arrangement Idler AssemblyBasket Tumbler Sail Switch Gas Models only Main Door SwitchHi-Limit Gas Models Only Lint Drawer Switch Automatic Reset ThermostatLint Drawer Steam Damper SystemIntroduction ServicingComputer Controls To Replace Computer To Replace Keyboard Label AssemblyTo Replace Microprocessor Temperature Sensor Probe Page To Replace Main Burner Orifices To Replace Gas Valve see burner illustration onTo Test and Adjust Gas Water Column Pressure To Convert from Natural Gas to L.P. Gas To Replace Burner Tubes To Replace DSI Module Sail Switch Assembly Gas Models Only To Adjust Sail Switch To Replace Sail SwitchTo Install New Main Door Glass To Replace Main Door AssemblyTo Replace Main Door Hinge Pad To Replace Front PanelTo Replace Small Idler Pulley Pulleys To Replace Tumbler PulleyTo Replace Motor Pulley To Replace Large Idler PulleyPage To Replace Tumbler Basket or Tumbler Basket Support Basket Alignment Lateral Side to Side AdjustmentImportant Never strike the shaft directly with a hammer To Replace Front Idler Shaft Pillow Block Bearing To Replace Front Basket Support Pillow Block BearingTo Replace Rear Idler Shaft Pillow Block Bearing Belt Tension Adjustment Basket to IdlerBelts See illustrations in section F Pulleys To Replace V-Belts Belt Tension Adjustment Motor to IdlerMotors To Replace Drive Motor Page To Replace Lint Drawer Switch Lint Drawer Assembly To Replace Lint ScreenImpellor No display on computer TroubleshootingComputer will not accept key pad entries Drive motor runs, burner is on, but basket will not turn Dryer will not start, but computer display indicators are onDryer operates but is taking too long to dry Dryer operates, probe sparks, but gas does not flowThermal overload for drive motor is tripping Dryer is cycling on burner hi-limit safety thermostatOverload for impellor fan motor is tripping Dryer does not start. Display reads door Display reads dSFL. Dryer Sensor Circuit FailureThere is excessive vibration coming from the basket Electrical Trouble Shooting Diagnostic LED Display Failure Codes Phase 5 OPL System DiagnosticsLED Display Indicators Page Page Cycle Status LED Display/CodesCY F LED Display CodesFill Computer Logic and Wiring Diagram Fault CodesPage No Display Condition Page Blower motor does not operate, drive motor runs Door condition Microprocessor reads Dsfl Motor Plate High and Low Voltage Technical InformationInformation on the Data Label Data Label Contacting American Dryer Corporation ADCHOW to USE a Manometer Using a ManometerAD-170SE Tool List ADC450400 1- 02/27/98-50