Page 48

2. "MTR" Output LED Indicator -

If the dryer is started and the motor is not operating, yet both the microprocessor controller display motor indicator dot and the "dOOr" input LED indicator are on, but the motor output LED indicator is off, then the fault is in the Phase 5 OPL microprocessor controller itself. If the motor is not operating and the "MOTOR" output indicator is on, then the problem is elsewhere (i.e., external of the microprocessor controller).

3."FWD" Output LED Indicator -

a.If the dryer is started and the blower motor is operating but the drive basket (tumbler) motor is not, yet the Phase 5 OPL microprocessor controller display "Forward" indicator dot is on, but the "FWD" (forward) motor output LED is off; the fault is the Phase 5 OPL microprocessor controller itself.

b.If the drive basket (tumbler) motor is not operating and the "FWD" indicator is on, then the problem (fault) is elsewhere (i.e., external of the Phase 5 OPL microprocessor controller).

4."REV" Output LED Indicator -

If the dryer is started and the blower motor is operating but the drive tumbler (basket) motor is not, yet the Phase 5 OPL microprocessor controller's display "REVERSE" indicator dot is on, but the "REV" (reverse) motor output LED is off, the fault is the Phase 5 OPL microprocessor controller itself. If the drive tumbler (basket) motor is not operating and the "REV" (reverse) indicator is on, then the problem (fault) is elsewhere (i.e., external of the Phase 5 OPL microprocessor controller).

44

Image 48
Contents AD-170 Retain This Manual In a Safe Place For Future Reference AD-170Page For Your Safety Table of Contents Sail Switch Assembly Safety Precautions Important InformationRoutine Maintenance CleaningAdjustments LubricationInstallation Requirements Enclosure, Air Supply, and Exhaust RequirementsOperational Service Check Procedure Electrical and Gas RequirementsComputer Panel Assembly Description of PartsControl Box DSI Module Gas Models OnlyGas Burner Assembly Drive MotorBlower Motor and Impellor Hz Gas Models Only Blower Motor and Impellor 50Hz, 60Hz Steam & 50Hz GasIdler Assembly Tumbler Bearing and Pulley ArrangementBasket Tumbler Main Door Switch Sail Switch Gas Models onlyHi-Limit Gas Models Only Automatic Reset Thermostat Lint Drawer SwitchLint Drawer Steam Damper SystemServicing IntroductionTo Replace Keyboard Label Assembly Computer Controls To Replace ComputerTo Replace Microprocessor Temperature Sensor Probe Page To Replace Gas Valve see burner illustration on To Replace Main Burner OrificesTo Test and Adjust Gas Water Column Pressure To Convert from Natural Gas to L.P. Gas To Replace Burner Tubes To Replace DSI Module Sail Switch Assembly Gas Models Only To Replace Sail Switch To Adjust Sail SwitchTo Replace Main Door Assembly To Install New Main Door GlassTo Replace Front Panel To Replace Main Door Hinge PadPulleys To Replace Tumbler Pulley To Replace Small Idler PulleyTo Replace Large Idler Pulley To Replace Motor PulleyPage Basket Alignment Lateral Side to Side Adjustment To Replace Tumbler Basket or Tumbler Basket SupportImportant Never strike the shaft directly with a hammer To Replace Front Basket Support Pillow Block Bearing To Replace Front Idler Shaft Pillow Block BearingBelt Tension Adjustment Basket to Idler To Replace Rear Idler Shaft Pillow Block BearingBelts See illustrations in section F Pulleys Belt Tension Adjustment Motor to Idler To Replace V-BeltsMotors To Replace Drive Motor Page Lint Drawer Assembly To Replace Lint Screen To Replace Lint Drawer SwitchImpellor Troubleshooting No display on computerComputer will not accept key pad entries Dryer will not start, but computer display indicators are on Drive motor runs, burner is on, but basket will not turnDryer operates, probe sparks, but gas does not flow Dryer operates but is taking too long to dryDryer is cycling on burner hi-limit safety thermostat Thermal overload for drive motor is trippingOverload for impellor fan motor is tripping Display reads dSFL. Dryer Sensor Circuit Failure Dryer does not start. Display reads doorThere is excessive vibration coming from the basket Electrical Trouble Shooting Phase 5 OPL System Diagnostics Diagnostic LED Display Failure CodesLED Display Indicators Page Page LED Display/Codes Cycle StatusLED Display Codes CY FFill Fault Codes Computer Logic and Wiring DiagramPage No Display Condition Page Blower motor does not operate, drive motor runs Door condition Microprocessor reads Dsfl Technical Information Motor Plate High and Low VoltageData Label Contacting American Dryer Corporation ADC Information on the Data LabelUsing a Manometer HOW to USE a ManometerAD-170SE Tool List ADC450400 1- 02/27/98-50