Service

Pressure Relief Procedure

WARNING

PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually

relieved to prevent the system from starting or spraying accidentally. To

reduce the risk of an injury from accidental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

Dare instructed to relieve the pressure, D stop spraying,

D check or service any of the system equipment, D or install or clean the spray nozzle.

1.Engage gun safety latch.

2.Turn ON/OFF switch to OFF.

3.Unplug power cord.

4.Disengage gun safety latch. Hold metal part of gun against grounded metal pail and trigger gun into pail to relieve pressure.

5.Engage gun safety latch.

6.Open any fluid drain valves in system. Leave drain valve open until ready to dispense again.

Pump Repair Kits

Pump

Repair Kit

 

 

244197

248212

 

 

244224

248213

 

 

244201

248213

 

 

244954

246341

 

 

244957

244958

 

 

245889

245819

 

 

245904

244200

 

 

246257

246341

 

 

248736

246341

 

 

248971

246341

 

 

277068

246341

 

 

287814

287813

 

 

287815

287813

 

 

287946

287945

 

 

Tools Needed

Vise

12 in. adjustable, open end wrench (2) Hammer, 20 oz maximum

Small screwdriver Throat Seal Liquid

Pick or long small screwdriver

Cleaning and Inspecting Parts

1.Clean and inspect parts. Pay particular attention to the ball seats in the intake valve and piston, which must have no nicks or wear, and to the inside of the sleeve and the outside of the piston rod, which must not be worn or scratched. Replace worn or damaged parts.

WARNING

COMPONENT RUPTURE HAZARD Never use sharp or pointed tools to

remove sleeve or other components which could result in pump rupture and

cause serious bodily injury. If the sleeve cannot be removed easily, return the sleeve and cylinder to your Graco distributor for removal.

2.Remove and clean the sleeve when you are repacking the pump.

4 309277

Image 4
Contents Displacement Pump Instructions -- Parts ListTable of Contents SymbolsEquipment Misuse Hazard Service Pressure Relief ProcedureCleaning and Inspecting Parts Pump Repair KitsRepair When Pump Is Off The Sprayer 245889, 287946 onlyAssembling the pump Tighten piston valve to piston rod as specified Grease piston packings and sleeve top edge 245889, 287946 only Repair When Pump Is On The Sprayer Skin Injection HazardRemove piston rod and sleeve Remove piston valve from piston rod with a wrench Ti3941a Use screwdriver to push retaining spring up 207 221 215 236 Technical Data Cross Sectional ReferenceParts -- Pump Model 244197, Series aParts -- Pumps 244224, 244201 Models 244224, Series a 244201, Series a 245904, Series aModel 244954, Series a PackingModel 244957, Series a Model 245889, Series B Model 287946, Series a Model 246257, Series a Model 287815, Series a Part No. Description QtyModel 287814 Series a Model 248736, Series a Parts -- Pump 248971 Model 248971, Series a 277068, Series aGraco Standard Warranty For Graco Canada Customers