Graco 308550ZAD important safety instructions Detail of Air Valve Bearings

Page 24

Service

1 Insert bearings tapered end first.

12

2 Press-fit bearings flush with surface of center housing (1).

3

Torque to 130–150 in-lb (15–17 NSm).

1 2

1

1

15

1

2

 

16 H

M

 

Detail of Air Valve Bearings

22

 

 

23

 

 

 

 

 

 

 

03951

 

 

 

25

3

19 1 2

 

 

03952B

Fig. 14

 

 

 

24 308550

Image 24
Contents Instructions Parts List Important Safety InstructionsTable of Contents ModelsSymbols Equipment Misuse HazardToxic Fluid Hazard Installation General InformationTighten Screws Before First Use Toxic Fluid HazardGrounding Ground all of this equipmentTypical FLOOR-MOUNT Installation Air LineInstallation of Remote Pilot Air Lines MountingsFluid Suction Line Fluid Outlet LineFlange Connections Bolt Tightening SequenceChanging the Orientation of the Fluid Inlet and Outlet Ports Fluid Pressure Relief ValveAir Exhaust Ventilation Fire and Explosion HazardVenting Exhaust AIR Pressure Relief Procedure Starting and Adjusting the PumpOperation Flush the Pump Before First UseMaintenance Troubleshooting Problem Cause SolutionTroubleshooting Service Repairing the Air ValveDisassembly Tools RequiredReassembly Ball Check Valve Repair Relieve the pressure. Disconnect all hosesDiaphragm Repair Reassembly Standard Diaphragms Reassembly Overmolded Diaphragms 105 19 402 24 104 403 Bearing and Air Gasket Removal Detail of Air Valve Bearings Pump Matrix Husky 2150 Polypropylene and Pvdf Pumps, Series aRepair Kit Matrix For Husky 2150 Polypropylene and Pvdf Pumps, Series aAir Motor Parts List Matrix Column PartsFluid Section Parts List Matrix Column MufflerSeat Parts List Matrix Column Ball Parts List Matrix ColumnDiaphragm Parts List Matrix Column 114 Torque Sequence Dimensions Front ViewSide View Pump Mounting Hole Pattern Dimension SST Center Aluminum Polypropylene Pvdf Cover Technical Data 14-0.8 MPa, 1.4-8 barPerformance Chart Feet metersPsi MPa, bar Fluid Flow GPM lpmGraco Warranties Graco Information