Graco 308550ZAD Ball Check Valve Repair, Relieve the pressure. Disconnect all hoses

Page 18

Service

Ball Check Valve Repair

1

Torque to 150–160 in–lb (17–18 NSm). See Torque Se- quence, page 31.

Tools Required

DTorque wrench

D10 mm socket wrench

DO-ring pick

Disassembly

NOTE: A Fluid Section Repair Kit is available. Refer to page 26 to order the correct kit for your pump. Parts included in the kit are marked with an asterisk, for example (201*). Use all the parts in the kit for the best results.

NOTE: To ensure proper seating of the balls (301), always replace the seats (201) when replacing the balls.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

1.Relieve the pressure. Disconnect all hoses.

2.Remove the pump from its mounting.

3.Using a 10 mm socket wrench, remove the eight bolts (106), and four washers (113), holding the outlet manifold (103) to the fluid covers (101). See Fig. 11.

4.Remove the seats (201), balls (301), and o-rings (202) from the manifold.

NOTE: Some models do not use o-rings (202).

5.Turn the pump over and remove the bolts (112), washers (114), and inlet manifold (102). Remove the seats (201), balls (301), and o-rings (202) from the fluid covers (101).

Reassembly

1.Clean all parts and inspect for wear or damage. Replace parts as needed.

2.Reassemble in the reverse order, following all notes in Fig. 11. Be sure the ball checks are as- sembled exactly as shown. The arrows (A) on the fluid covers (101) must point toward the outlet manifold (103).

18 308550

2Arrow (A) must point toward outlet manifold (103).

3Not used on some models.

106 1

113

103

301*

201*

202* 3

101

A 2

301*

201*

202* 3

102

114

1112

 

04619C

Fig. 11

 

 

 

Image 18
Contents Instructions Parts List Important Safety InstructionsTable of Contents ModelsSymbols Equipment Misuse HazardToxic Fluid Hazard Tighten Screws Before First Use InstallationGeneral Information Toxic Fluid HazardGrounding Ground all of this equipmentTypical FLOOR-MOUNT Installation Air LineFluid Suction Line Installation of Remote Pilot Air LinesMountings Fluid Outlet LineFlange Connections Bolt Tightening SequenceChanging the Orientation of the Fluid Inlet and Outlet Ports Fluid Pressure Relief ValveAir Exhaust Ventilation Fire and Explosion HazardVenting Exhaust AIR Operation Pressure Relief ProcedureStarting and Adjusting the Pump Flush the Pump Before First UseMaintenance Troubleshooting Problem Cause SolutionTroubleshooting Disassembly ServiceRepairing the Air Valve Tools RequiredReassembly Ball Check Valve Repair Relieve the pressure. Disconnect all hosesDiaphragm Repair Reassembly Standard Diaphragms Reassembly Overmolded Diaphragms 105 19 402 24 104 403 Bearing and Air Gasket Removal Detail of Air Valve Bearings Pump Matrix Husky 2150 Polypropylene and Pvdf Pumps, Series aRepair Kit Matrix For Husky 2150 Polypropylene and Pvdf Pumps, Series aAir Motor Parts List Matrix Column PartsFluid Section Parts List Matrix Column MufflerSeat Parts List Matrix Column Ball Parts List Matrix ColumnDiaphragm Parts List Matrix Column 114 Torque Sequence Dimensions Front ViewSide View Pump Mounting Hole Pattern Dimension SST Center Aluminum Polypropylene Pvdf Cover Technical Data 14-0.8 MPa, 1.4-8 barPsi MPa, bar Performance ChartFeet meters Fluid Flow GPM lpmGraco Warranties Graco Information