Graco 308550ZAD important safety instructions Air Line, Typical FLOOR-MOUNT Installation

Page 7

Installation

Air Line

WARNING

A bleed-type master air valve (B) is required in your system to relieve air trapped between this valve and the pump. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury, including splashing in the eyes or on the skin, injury from moving parts, or contamination from hazardous fluids. See Fig. 2.

1.Install the air line accessories as shown in Fig. 2. Mount these accessories on the wall or on a bracket. Be sure the air line supplying the acces- sories is electrically conductive.

a.Install an air regulator (C) and gauge to control the fluid pressure. The fluid outlet pressure will be the same as the setting of the air regulator.

TYPICAL FLOOR-MOUNT INSTALLATION

KEY FOR FIG. 2

AElectrically conductive air supply hose

BBleed-type master air valve (required for pump)

CAir regulator

DAir line quick disconnect

E

Master air valve (for accessories)

A

F

Air line filter

 

G

Fluid suction hose

 

H

Fluid supply

 

J

Fluid drain valve (required)

 

K

Fluid shutoff valve

D

l

Fluid hose

 

N1/2 npt(f) air inlet port R 2” fluid inlet flange S 2” fluid outlet flange

Y Ground wire (required; see page 6

for installation instructions)

Y

b.Locate one bleed-type master air valve (B) close to the pump and use it to relieve trapped air. See the WARNING at left. Locate the other master air valve (E) upstream from all air line accessories and use it to isolate them during cleaning and repair.

c.The air line filter (F) removes harmful dirt and moisture from the compressed air supply.

2.Install an electrically conductive, flexible air hose

(A) between the accessories and the 1/2 npt(f) pump air inlet (N). See Fig. 2. Use a minimum 1/2” (13 mm) ID air hose.

3.Screw an air line quick disconnect coupler (D) onto the end of the air hose (A); be sure the coupler porting is large enough to not restrict the air flow, which will affect pump performance. Screw the mating fitting into the pump air inlet snugly. Do not connect the coupler (D) to the fitting until you are ready to operate the pump.

BC F E

SK L

N

J

H

RG

Fig. 2

04614B

 

 

308550 7

Image 7
Contents Important Safety Instructions Instructions Parts ListModels Table of ContentsEquipment Misuse Hazard Symbols Toxic Fluid Hazard Toxic Fluid Hazard InstallationGeneral Information Tighten Screws Before First UseGround all of this equipment GroundingAir Line Typical FLOOR-MOUNT InstallationFluid Outlet Line Installation of Remote Pilot Air LinesMountings Fluid Suction LineBolt Tightening Sequence Flange ConnectionsFluid Pressure Relief Valve Changing the Orientation of the Fluid Inlet and Outlet PortsFire and Explosion Hazard Air Exhaust VentilationVenting Exhaust AIR Flush the Pump Before First Use Pressure Relief ProcedureStarting and Adjusting the Pump OperationMaintenance Problem Cause Solution TroubleshootingTroubleshooting Tools Required ServiceRepairing the Air Valve DisassemblyReassembly Relieve the pressure. Disconnect all hoses Ball Check Valve RepairDiaphragm Repair Reassembly Standard Diaphragms Reassembly Overmolded Diaphragms 105 19 402 24 104 403 Bearing and Air Gasket Removal Detail of Air Valve Bearings Husky 2150 Polypropylene and Pvdf Pumps, Series a Pump MatrixFor Husky 2150 Polypropylene and Pvdf Pumps, Series a Repair Kit MatrixParts Air Motor Parts List Matrix ColumnMuffler Fluid Section Parts List Matrix ColumnBall Parts List Matrix Column Seat Parts List Matrix ColumnDiaphragm Parts List Matrix Column 114 Torque Sequence Front View DimensionsSide View Pump Mounting Hole Pattern Dimension SST Center Aluminum Polypropylene Pvdf Cover 14-0.8 MPa, 1.4-8 bar Technical DataFluid Flow GPM lpm Performance ChartFeet meters Psi MPa, barGraco Information Graco Warranties