Emerson 3051SF manual Remote Display Wiring and Power Up

Page 10

Quick Installation Guide

Rosemount 3051S

00825-0100-4801, Rev KB December 2010

STEP 4 CONTINUED...

Remote Display Wiring and Power Up

The Remote Mount Display and Interface system consists of a local transmitter and a remote mount LCD display assembly. The local 3051S transmitter assembly includes a Junction Box housing with a three position terminal block integrally mounted to a sensor module. The remote mount LCD display assembly consists of a dual compartment PlantWeb housing with a seven position terminal block. See Figure 8 on page 11 for complete wiring instructions. The following is a list of necessary information specific to the Remote Mount Display system:

Each terminal block is unique for the remote display system.

A 316 SST housing adapter is permanently secured to the remote mount LCD display PlantWeb housing, providing an external ground and a means for field mounting with the provided mounting bracket.

A cable is required for wiring between the transmitter and remote mount LCD display. The cable length is limited to 100 ft.

50 ft. (option M8) or 100 ft. (option M9) cable is provided for wiring between the transmitter and remote mount LCD display. Option M7 does not include cable; see recommended specifications below:

Cable type: Recommend Belden 3084A DeviceNet cable or Belden 123084A Armored DeviceNet cable. Other comparable cable may be used as long as it has independent dual twisted shielded pair wires with an outer shield. The Power wires must be 22 AWG minimum and the CAN communication wires must be 24 AWG minimum.

Cable length: Up to 100 feet depending upon cable capacitance.

Cable capacitance: The capacitance from the CAN communications line to the CAN return line as wired must be less than 5000 picofarads total. This allows up to 50 picofarads per foot for a 100 foot cable.

10

Image 10
Contents Quick Installation Guide ¢00825-0100-4801J¤Electrical shock can result in death or serious injury Explosions could result in death or serious injuryProcess leaks may cause harm or result in death Conduit/Cable EntriesGas Flow Applications Mount the TransmitterLiquid Flow Applications Steam Flow ApplicationsStep Bolting Considerations Common Transmitter AssembliesRing Rings with Flange AdaptersFlange Adapter Ptfe BasedInline Gage Transmitter Orientation Consider Housing RotationSET Switches and Jumpers PlantWeb Junction BoxConnect Wiring and Power UP PlantWeb Housing Wiring Junction Box Housing WiringSignal Wiring Grounding WiringRemote Display Wiring and Power Up Remote Mount Display wiring diagram Junction Box Housing Remote Mount DisplayQuick Connect Wiring Rosemount 3051S Quick Connect Exploded ViewConduit Electrical Connector Wiring Option GE or GM Power SupplyVerify Configuration Field Communicator User InterfaceFunction Fast Key Sequence Units 1,2 Upper Sensor Trim 1,1 Zero Trim 1,3 Trim the Transmitter Using the Field CommunicatorUsing the Transmitter Zero Adjustment Button Zero TrimInstallation Safety Instrumented Systems3051S Safety-Certified Identification ConfigurationRosemount Alarm Level Switches installedSwitches not installed Namur Alarm LevelVisual Inspection Operation and MaintenanceProof Test and Inspection Special ToolsReference Hazardous Locations Certifications Product CertificationsApproved Manufacturing Locations North American CertificationsEuropean Certifications Loop / Power GroupsRTD Assembly 3051SFx Option T or R Special Conditions for Safe UseRosemount 3051S China Nepsi Certifications Japanese CertificationsCertificate Description Inmetro Certifications IECEx CertificationsLoop / Power Groups Combinations of Certifications KD Combination of E5, I5, E6, I6, E1,DOC Rosemount 3051S Schedule Rosemount 3051S Rosemount 3051S Rosemount 3051S
Related manuals
Manual 32 pages 28.03 Kb Manual 36 pages 50 Kb

3051SF, 3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.