PRODUCT CERTIFICATIONS

Approved Manufacturing Locations

Rosemount Inc. — Chanhassen, Minnesota USA

Fisher-Rosemount GmbH & Co. — Wessling, Germany

Emerson Process Management Asia Pacific Private Limited — Singapore

Beijing Rosemount Far East Instrument Co., LTD — Beijing, China

Emerson Process Management LTDA — Sorocaba, Brazil

Emerson Process Management (India) Pvt. Ltd. — Daman, India

European Directive Information

The EC declaration of conformity can be found on page 29. The most recent revision can be found at www.rosemount.com.

Ordinary Location Certification for FM Approvals

As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM Approvals, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

Hazardous Locations Certifications

North American Certifications

FM Approvals

E5 Explosion proof for Class I, Division 1, Groups B, C, and D, T5 (Ta = 85 °C); dust-ignition proof for Class II and Class III, Division 1, Groups E, F, and G, T5 (Ta = 85 °C); hazardous locations; enclosure Type 4X, conduit seal not required when installed according to Rosemount drawing 03151-1003.

I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D, T4 (Ta = 70 °C); Class II, Division 1, Groups E, F, and G; Class III, Division 1; Class I, Zone 0 AEx ia IIC T4 (Ta = 70 °C) when connected in accordance with Rosemount drawing 03151-1006; Non-incendive for Class I, Division 2, Groups A, B, C, and D; T4 (Ta = 70 °C); Enclosure Type 4X

For entity parameters see control drawing 03151-1006.

Canadian Standards Association (CSA)

All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003.

E6 Explosion-Proof for Class I, Division 1, Groups B, C, and D; Dust-Ignition-Proof for Class II and Class III, Division 1, Groups E, F, and G; suitable for Class I, Division 2, Groups A, B, C, and D, when installed per Rosemount drawing 03151-1013, CSA Enclosure Type 4X; conduit seal not required; Dual Seal.

I6 Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings 03151-1016; Dual Seal.

For entity parameters see control drawing 03151-1016.

22

Image 22
Contents Quick Installation Guide ¢00825-0100-4801J¤Electrical shock can result in death or serious injury Explosions could result in death or serious injuryProcess leaks may cause harm or result in death Conduit/Cable EntriesGas Flow Applications Mount the TransmitterLiquid Flow Applications Steam Flow ApplicationsStep Bolting Considerations Common Transmitter AssembliesRing Rings with Flange AdaptersFlange Adapter Ptfe BasedInline Gage Transmitter Orientation Consider Housing RotationSET Switches and Jumpers PlantWeb Junction BoxConnect Wiring and Power UP PlantWeb Housing Wiring Junction Box Housing WiringSignal Wiring Grounding WiringRemote Display Wiring and Power Up Remote Mount Display wiring diagram Junction Box Housing Remote Mount DisplayQuick Connect Wiring Rosemount 3051S Quick Connect Exploded ViewConduit Electrical Connector Wiring Option GE or GM Power SupplyVerify Configuration Field Communicator User InterfaceFunction Fast Key Sequence Units 1,2 Upper Sensor Trim 1,1 Zero Trim 1,3 Trim the Transmitter Using the Field CommunicatorUsing the Transmitter Zero Adjustment Button Zero TrimInstallation Safety Instrumented Systems3051S Safety-Certified Identification ConfigurationRosemount Alarm Level Switches installedSwitches not installed Namur Alarm LevelVisual Inspection Operation and MaintenanceProof Test and Inspection Special ToolsReference Hazardous Locations Certifications Product CertificationsApproved Manufacturing Locations North American CertificationsEuropean Certifications Loop / Power GroupsRTD Assembly 3051SFx Option T or R Special Conditions for Safe UseRosemount 3051S China Nepsi Certifications Japanese CertificationsCertificate Description Inmetro Certifications IECEx CertificationsLoop / Power Groups Combinations of Certifications KD Combination of E5, I5, E6, I6, E1,DOC Rosemount 3051S Schedule Rosemount 3051S Rosemount 3051S Rosemount 3051S
Related manuals
Manual 32 pages 28.03 Kb Manual 36 pages 50 Kb

3051SF, 3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.