Emerson 3051SF manual Inline Gage Transmitter Orientation, Consider Housing Rotation

Page 7

Quick Installation Guide

00825-0100-4801, Rev KB December 2010

Rosemount 3051S

STEP 1 CONTINUED...

Inline Gage Transmitter Orientation

The low side pressure port (atmospheric reference) on the inline gage transmitter is located under the sensor module neck label. (See Figure 3.)

Keep the vent path free of any obstruction, including but not limited to paint, dust, and lubrication by mounting the transmitter so that any contaminants can drain away.

Figure 3. Inline Gage Transmitter

Low side pressure port (under neck label)

STEP 2: CONSIDER HOUSING ROTATION

To improve field access to wiring or to better view the optional LCD display:

1.Loosen the housing rotation set screw.

2.First rotate the housing clockwise to the desired location. If the desired location cannot be achieved due to thread limit, rotate the housing counter clockwise to the desired location (up to 360° from thread limit).

3.Retighten the housing rotation set screw.

Figure 4. Transmitter Housing Set Screw

PlantWeb

Junction Box

Housing Rotation Set

Screw (3/32-inch)

STEP 3: SET SWITCHES AND JUMPERS

If alarm and security adjustment option is not installed, the transmitter will operate normally with the default alarm condition alarm high and the security off.

Figure 5. Transmitter Switch and Jumper Configuration

PlantWeb

Meter/

Adjustment

Module

SecurityAlarm

Slide the security and alarm switches into the preferred position by using a small screwdriver. (An LCD display or an adjustment module must be in place to activate the switches.)

Junction Box

Security Alarm

Pull the jumpers out and rotate 90° into desired position to set the security and alarm.

7

Image 7
Contents ¢00825-0100-4801J¤ Quick Installation GuideConduit/Cable Entries Explosions could result in death or serious injuryProcess leaks may cause harm or result in death Electrical shock can result in death or serious injurySteam Flow Applications Mount the TransmitterLiquid Flow Applications Gas Flow Applications Step Common Transmitter Assemblies Bolting ConsiderationsPtfe Based Rings with Flange AdaptersFlange Adapter RingPlantWeb Junction Box Consider Housing RotationSET Switches and Jumpers Inline Gage Transmitter OrientationPlantWeb Housing Wiring Junction Box Housing Wiring Connect Wiring and Power UPWiring Signal Wiring GroundingRemote Display Wiring and Power Up Junction Box Housing Remote Mount Display Remote Mount Display wiring diagramRosemount 3051S Quick Connect Exploded View Quick Connect WiringPower Supply Conduit Electrical Connector Wiring Option GE or GMField Communicator User Interface Verify ConfigurationFunction Fast Key Sequence Units 1,2 Upper Sensor Trim 1,1 Zero Trim 1,3 Zero Trim Using the Field CommunicatorUsing the Transmitter Zero Adjustment Button Trim the TransmitterConfiguration Safety Instrumented Systems3051S Safety-Certified Identification InstallationNamur Alarm Level Switches installedSwitches not installed Rosemount Alarm LevelSpecial Tools Operation and MaintenanceProof Test and Inspection Visual InspectionReference North American Certifications Product CertificationsApproved Manufacturing Locations Hazardous Locations CertificationsSpecial Conditions for Safe Use Loop / Power GroupsRTD Assembly 3051SFx Option T or R European CertificationsRosemount 3051S China Nepsi Certifications Japanese CertificationsCertificate Description IECEx Certifications Inmetro CertificationsLoop / Power Groups KD Combination of E5, I5, E6, I6, E1, Combinations of CertificationsDOC Rosemount 3051S Schedule Rosemount 3051S Rosemount 3051S Rosemount 3051S
Related manuals
Manual 32 pages 28.03 Kb Manual 36 pages 50 Kb

3051SF, 3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.