Emerson 3051SF manual Quick Connect Wiring, Rosemount 3051S Quick Connect Exploded View

Page 12

Quick Installation Guide

Rosemount 3051S

00825-0100-4801, Rev KB December 2010

STEP 4 CONTINUED...

NOTE

Wire colors provided on page 11 are per Belden 3084A DeviceNet cable. Wire color may vary depending on cable selected.

Belden 3084A DeviceNet cable includes a ground shield. This shield must be connected to earth ground at either the sensor module or the Remote Display, but not both.

Quick Connect Wiring

As standard, the 3051S Quick Connect arrives properly assembled to the sensor module and is ready for installation. Cordsets and Field Wireable Connectors (in shaded area) are sold separately.

Figure 9. Rosemount 3051S Quick Connect Exploded View

Straight Field Wireable

Right Angle Field Wireable Connector(2)(3)

Connector(1)(3)Cordset(4)

Coupling Nut

Quick Connect

Quick Connect Coupling Nut

Housing

(1) Order part number 03151-9063-0001.

(2) Order part number 03151-9063-0002.

(3) Field wiring supplied by customer.

(4) Supplied by cordset vendor.

IMPORTANT

If Quick Connect is ordered as a 300S spare housing or is removed from the sensor module, follow the instructions below for proper assembly prior to field wiring.

1.Place the Quick Connect onto the sensor module. To ensure proper pin alignment, remove coupling nut prior to installing quick connect onto the sensor module.

2.Place coupling nut over quick connect and wrench tighten to a maximum of 300 in-lb. (34 N-m).

3.Tighten the set screw using a 3/32-in. hex wrench.

4.Install Cordset/ Field Wireable Connectors onto the Quick Connect. Do not over tighten.

Figure 10. Quick Connect Housing Pin-Out

 

“+”

For other wiring details, refer to pin-out

“–”

drawing and the cordset manufacturer’s

No Connection

installation instructions.

 

 

Ground

12

Image 12
Contents Quick Installation Guide ¢00825-0100-4801J¤Explosions could result in death or serious injury Process leaks may cause harm or result in deathElectrical shock can result in death or serious injury Conduit/Cable EntriesMount the Transmitter Liquid Flow ApplicationsGas Flow Applications Steam Flow ApplicationsStep Bolting Considerations Common Transmitter AssembliesRings with Flange Adapters Flange AdapterRing Ptfe BasedConsider Housing Rotation SET Switches and JumpersInline Gage Transmitter Orientation PlantWeb Junction BoxConnect Wiring and Power UP PlantWeb Housing Wiring Junction Box Housing WiringSignal Wiring Grounding WiringRemote Display Wiring and Power Up Remote Mount Display wiring diagram Junction Box Housing Remote Mount DisplayQuick Connect Wiring Rosemount 3051S Quick Connect Exploded ViewConduit Electrical Connector Wiring Option GE or GM Power SupplyVerify Configuration Field Communicator User InterfaceFunction Fast Key Sequence Units 1,2 Upper Sensor Trim 1,1 Zero Trim 1,3 Using the Field Communicator Using the Transmitter Zero Adjustment ButtonTrim the Transmitter Zero TrimSafety Instrumented Systems 3051S Safety-Certified IdentificationInstallation ConfigurationSwitches installed Switches not installedRosemount Alarm Level Namur Alarm LevelOperation and Maintenance Proof Test and InspectionVisual Inspection Special ToolsReference Product Certifications Approved Manufacturing LocationsHazardous Locations Certifications North American CertificationsLoop / Power Groups RTD Assembly 3051SFx Option T or REuropean Certifications Special Conditions for Safe UseRosemount 3051S Japanese Certifications China Nepsi CertificationsCertificate Description Inmetro Certifications IECEx CertificationsLoop / Power Groups Combinations of Certifications KD Combination of E5, I5, E6, I6, E1,DOC Rosemount 3051S Schedule Rosemount 3051S Rosemount 3051S Rosemount 3051S
Related manuals
Manual 32 pages 28.03 Kb Manual 36 pages 50 Kb

3051SF, 3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.