Emerson 3051SF Remote Mount Display wiring diagram, Junction Box Housing Remote Mount Display

Page 11

Quick Installation Guide

00825-0100-4801, Rev KB December 2010

Rosemount 3051S

STEP 4 CONTINUED...

Intrinsic Safety Consideration: The transmitter assembly with remote display has been approved with Belden 3084A DeviceNet cable. Alternate cable may be used as long as the transmitter with remote display and cable is configured according to the installation control drawing or certificate. Refer to appropriate approval certificate or control drawing in Appendix B of the 3051S reference manual for remote cable IS requirements.

IMPORTANT

Do not apply power to the remote communications terminal. Follow wiring instructions carefully to prevent damage to system components.

Figure 8. Remote Mount Display wiring diagram

Junction Box Housing

Remote Mount Display

(white) 24 AWG

(blue) 24 AWG

(black) 22 AWG

(red) 22 AWG

4-20 mA

11

Image 11
Contents ¢00825-0100-4801J¤ Quick Installation GuideConduit/Cable Entries Explosions could result in death or serious injuryProcess leaks may cause harm or result in death Electrical shock can result in death or serious injurySteam Flow Applications Mount the TransmitterLiquid Flow Applications Gas Flow ApplicationsStep Common Transmitter Assemblies Bolting ConsiderationsPtfe Based Rings with Flange AdaptersFlange Adapter RingPlantWeb Junction Box Consider Housing RotationSET Switches and Jumpers Inline Gage Transmitter OrientationPlantWeb Housing Wiring Junction Box Housing Wiring Connect Wiring and Power UPWiring Signal Wiring GroundingRemote Display Wiring and Power Up Junction Box Housing Remote Mount Display Remote Mount Display wiring diagramRosemount 3051S Quick Connect Exploded View Quick Connect WiringPower Supply Conduit Electrical Connector Wiring Option GE or GMField Communicator User Interface Verify ConfigurationFunction Fast Key Sequence Units 1,2 Upper Sensor Trim 1,1 Zero Trim 1,3 Zero Trim Using the Field CommunicatorUsing the Transmitter Zero Adjustment Button Trim the TransmitterConfiguration Safety Instrumented Systems3051S Safety-Certified Identification InstallationNamur Alarm Level Switches installedSwitches not installed Rosemount Alarm LevelSpecial Tools Operation and MaintenanceProof Test and Inspection Visual InspectionReference North American Certifications Product CertificationsApproved Manufacturing Locations Hazardous Locations CertificationsSpecial Conditions for Safe Use Loop / Power GroupsRTD Assembly 3051SFx Option T or R European CertificationsRosemount 3051S Certificate Description Japanese CertificationsChina Nepsi Certifications IECEx Certifications Inmetro CertificationsLoop / Power Groups KD Combination of E5, I5, E6, I6, E1, Combinations of CertificationsDOC Rosemount 3051S Schedule Rosemount 3051S Rosemount 3051S Rosemount 3051S
Related manuals
Manual 32 pages 28.03 Kb Manual 36 pages 50 Kb

3051SF, 3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.