STEP 1 CONTINUED...

Figure 2. Torque values for the flange and flange adapter bolts

 

Bolt Material

Head Markings

Initial Torque Final Torque

Carbon Steel (CS)

Stainless Steel (SST)

316

316 R

 

 

300 in.-lbs.

650 in.-lbs.

B7M

 

 

 

150 in.-lbs.

300 in.-lbs.

 

 

B8M

316

STM SW

316 316

O-rings with Flange Adapters

WARNING

Failure to install proper flange adapter O-rings may cause process leaks, which can result in death or serious injury. The two flange adapters are distinguished by unique O-ring grooves. Only use the O-ring that is designed for its specific flange adapter, as shown below.

Rosemount 3051S / 3051 / 2051 / 3095

Flange Adapter

O-ring

PTFE Based

Elastomer

Rosemount 1151

Flange Adapter

O-ring

PTFE

Elastomer

Whenever the flanges or adapters are removed, visually inspect the o-rings. Replace them if there are any signs of damage, such as nicks or cuts. If you replace the o-rings, re-torque the flange bolts and alignment screws after installation to compensate for seating of the PTFE o-ring.

6

Image 6
Contents Quick Installation Guide ¢00825-0100-4801J¤Electrical shock can result in death or serious injury Explosions could result in death or serious injuryProcess leaks may cause harm or result in death Conduit/Cable Entries Gas Flow Applications Mount the Transmitter Liquid Flow Applications Steam Flow ApplicationsStep Bolting Considerations Common Transmitter AssembliesRing Rings with Flange AdaptersFlange Adapter Ptfe BasedInline Gage Transmitter Orientation Consider Housing RotationSET Switches and Jumpers PlantWeb Junction BoxConnect Wiring and Power UP PlantWeb Housing Wiring Junction Box Housing WiringSignal Wiring Grounding WiringRemote Display Wiring and Power Up Remote Mount Display wiring diagram Junction Box Housing Remote Mount DisplayQuick Connect Wiring Rosemount 3051S Quick Connect Exploded ViewConduit Electrical Connector Wiring Option GE or GM Power SupplyVerify Configuration Field Communicator User InterfaceFunction Fast Key Sequence Units 1,2 Upper Sensor Trim 1,1 Zero Trim 1,3 Trim the Transmitter Using the Field CommunicatorUsing the Transmitter Zero Adjustment Button Zero TrimInstallation Safety Instrumented Systems3051S Safety-Certified Identification ConfigurationRosemount Alarm Level Switches installedSwitches not installed Namur Alarm LevelVisual Inspection Operation and MaintenanceProof Test and Inspection Special ToolsReference Hazardous Locations Certifications Product CertificationsApproved Manufacturing Locations North American CertificationsEuropean Certifications Loop / Power GroupsRTD Assembly 3051SFx Option T or R Special Conditions for Safe UseRosemount 3051S Japanese Certifications China Nepsi CertificationsCertificate Description Inmetro Certifications IECEx CertificationsLoop / Power Groups Combinations of Certifications KD Combination of E5, I5, E6, I6, E1,DOC Rosemount 3051S Schedule Rosemount 3051S Rosemount 3051S Rosemount 3051S
Related manuals
Manual 32 pages 28.03 Kb Manual 36 pages 50 Kb

3051SF, 3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.