Omega Engineering i.BTX-M manual Default IP Address, Port Number, Example C\Telnet 192.168.1.200

Page 14

3.5.1 Default IP Address

The iServer is shipped with a default IP address set to 192.168.1.200 and Subnet Mask of 255.255.255.0. If you are going to use a Web browser or Telnet program to access the iServer using its default IP address, make sure that the PC from which you’re establishing the connection has an IP address that is in the same range as the iServer’s IP address (192.168.1.x, where x can be any number from 1 to 254.

Your PC’s IP address cannot be the same as the iServer’s IP address).

You also need to make sure that your PC’s Subnet Mask is 255.255.255.0. This is a good way to access the iServer over the network and make any configuration changes needed. If 192.168.1.200 is already in use on your network, use an Ethernet crossover cable between your computer and the iServer to change the IP address or any other settings within the iServer.

3.6 Port Number

All TCP connections are defined by the IP address and a port number. A port number is an internal address that provides an interface between an application running on your computer and the network through the TCP/IP protocol.

There are three default TCP socket port numbers assigned to the iServer:

1.Port (socket) number 1000 when using HTTPGET program.

2.Port (socket) number 2000 when trying to access the sensor (probe) connected to the port of the iServer to receive ASCII data.

3.Port (socket) number 2002 when trying to access the iServer itself for Power Recycling the iServer remotely. This can be done using Windows standard Telnet application.

Power recycling the iServer can also be done through the iServer’s Web Server (see Section 4.2).

Telnet stands for Telecommunications Network, is a protocol that provides a way for users (or clients) to connect to computers (or servers) on a network, whether in the next building or across the world.

Example: C:\>Telnet 192.168.1.200 2002

You will then get the following screen.

C:\ Telnet 192.168.1.200

Type "reset" to reboot the server

The default Admin. Password

Firmware Version x.xx Admin. Password:00000000

Admin. Login Successful reset

The unit will reset in 5 seconds

_

Figure 3.3 Telnet Login into the iServer

You can open a Telnet session using other terminal emulation programs like Tera Term Pro (downloadable from the internet), which is a free software for MS-Windows. It supports VT100 emulation, Telnet connection and serial com port connections.

10

Image 14
Contents User’s Guide OMEGAnet On-Line Service Internet e-mail Info@omega.com Servicing North AmericaTable of Contents List of Figures IServer and iLD Big Display on the Ethernet NetworkFeatures Part Introduction Computer with Standard Web Browser Mounting DIP SwitchesPart 2 Hardware Parts of the iServer Unit Parts of the iServer Unit Parts of iServer UnitDisassembly Instruction Opening the UnitRunning on Battery Power 2 10Base-T Crossover WiringRelay Wiring Connections Network Communication Interfaces 1 10Base-T RJ-45 PinoutEthernet MAC Address Part Network ConfigurationNetwork Protocols Dhcp IP AddressExample C\Telnet 192.168.1.200 Default IP AddressPort Number Testing the Connection Part OperationsAssigning an IP Address using iCONNECT ICONNECT SoftwareSetting a New IP Address over the Network Access ControlSetup and Operation using the iServer Web IServer HomeRead Sensor Java Runtime Environment 1.4 Setup instructions Read SensorDiagnostics Java Runtime Environment 1.5 5.0 Setup instructionsAccessing iServer units using the internet Adjustable Chart Pressure/TempRetrieving Data from Flash Option10 Access Control Host Name Refer to .4, DNS#2 RTC is set, and recording is in progress Configuration#1 RTC is not set and Flash Card is empty #4 RTC is not set and the Flash Card is not empty11 Configuration Sensor/Device SetupReal Time Clock THi/Lo BHi/Lo BHi/Hi BLo/Hi BLo/LoFlash Recording Terminal Server Remote Access Remote End Char Sensor ParametersT75.7F P1014.9mbar Telnet Setup Httpget ProgramHttpget using Port ResponseHttpget -r -S 00000000 Where Httpget and ARP to setup Device IP AddressApr -s 192.168.1.200 00-03-34-00-00-06-b6 14 ARP Commands and Responses ARP ProtocolILOG Software 15 iLOG Software Logging DataInstallation Mail Notifier Software17 iServer Mail Notifier Profile Setup Email Connection Mapi AccessDevice Setting and Configuration Device setup requires 18 iServer Mail Notifier Device SettingPower Part 5 SpecificationsTemperature T PackagingRemote Access Tunneling Network InterfaceAppendix a Glossary Appendix B IP Address Class B Appendix C IP NetmaskMask Dotted Notation Mask Binary Mask Bits Class a Class CDec Hex Binary Appendix D Ascii ChartAscii Dec Hex Binary Char No Parity No parityDec Hex Ctrl Key Definition Appendix D Ascii Chart ContinuationAscii Control Codes Dec Hex Ctrl Key Definition Char EquivPart Approvals Information CE Approval Measurement CategoryWARRANTY/DISCLAIMER Shop on line at omega.com