PART 5 SPECIFICATIONS

SENSOR SPECIFICATIONS BAROMETRIC PRESSURE (B) Accuracy/Range:

±2.0 mbar / 0-1100 mbar (0-110 KPa)

Resolution: 0.1 mbar

TEMPERATURE (T)

Range*: 0°C to 70°C (32°F to 158°F)

Accuracy*:

±0.8°C @ 20°C (± 1.5°F @ 68°F)

±2°C for -40 to 125°C

(± 3.6°F for -40 to 257°F)

*Note: extended temperature range is for Industrial Probe only, the iServer’s operating temperature is 0 to 70°C. Response Time: 5 seconds

(63% slowly moving air)

Repeatability: ±0.1°C

Resolution: 0.01°C, 14bit

PROBE PHYSICAL DIMENSIONS Wand Probe:

159 mm lg x 19 mm dia (6.25” x 0.75")

Cable with DB9 connector:

152 mm long (6")

Cable operating temp:

0 to 80°C (32 to 176°F)

Industrial Probe:

137mm lg x 16mm dia (5” x 0.63")

Cable with DB9 or stripped leads: 6.1m long (20’)

Cable operating temp:

0 to 105°C (32 to 221°F)

iSERVER SPECIFICATIONS INTERFACE

Ethernet: 10Base-T (RJ45)

Sensor: Digital 4-wire (DB-9)

Supported Protocols:

TCP/IP, UDP/IP, ARP, ICMP, DHCP, DNS,

HTTP, and Telnet

LED Indicators: Network Activity,

Network Link, and Diagnostics

LCD Display: 16 digits, 6mm (0.23”)

Processor: Enhanced 8051, 22 MHz

Memory: 512 Kbytes Flash, 16 Kbytes

SRAM

Memory Data Flash Card: 2 Mbytes or 2 months of data storage at 10 second logging intervals, or 1 year at 1 minute logging intervals. Atmel# AT45DCB002

Optional Flash Cards:

4 Mbyte (2 years at 1 minute intervals)

8 Mbyte (4 years at 1 minute intervals)

Relay Outputs:

Two relays 1.5A @ 30Vdc Management: Device configuration and monitoring through embedded WEB server

Embedded WEB Server: Serves WEB pages containing real-time data and live updated charts within definable time intervals.

Agency Approvals: FCC-B, CE

Software: Field firmware upgradeable.

Including an Excel program for automatic data logging within definable time intervals, compatible with all Windows operating systems.

POWER

Power Input: 9-12 Vdc

Consumption: 2.5 W max.

Safety Qualified ac Power Adapter Nominal Output: 9 Vdc @ 0.5 A Input: 100-240 Vac, 50/60Hz

Battery: 9 Vdc, alkaline approximately 650 mA hours

ENVIRONMENTAL Operating Temperature: 0 to 70°C (32 to 158°F)

Storage Temperature:

-40 to 125°C (-40 to 257°F)

PACKAGING

Material: Metal case with flange mount iServer Housing Dimensions:

36.6H x 62W x 90Dmm

(1.44 x 2.93 x 3.56 “) Weight: 298 g (0.8 lbs.)

35

Image 39
Contents User’s Guide Servicing North America OMEGAnet On-Line Service Internet e-mail Info@omega.comTable of Contents IServer and iLD Big Display on the Ethernet Network List of FiguresFeatures Part Introduction Computer with Standard Web Browser DIP Switches Part 2 HardwareMounting Parts of the iServer Unit Parts of iServer Unit Parts of the iServer UnitOpening the Unit Disassembly InstructionNetwork Communication Interfaces 1 10Base-T RJ-45 Pinout 2 10Base-T Crossover WiringRelay Wiring Connections Running on Battery PowerPart Network Configuration Network ProtocolsEthernet MAC Address IP Address DhcpDefault IP Address Port NumberExample C\Telnet 192.168.1.200 Part Operations Testing the ConnectionICONNECT Software Assigning an IP Address using iCONNECTAccess Control Setting a New IP Address over the NetworkIServer Home Setup and Operation using the iServer WebRead Sensor Read Sensor Java Runtime Environment 1.4 Setup instructionsJava Runtime Environment 1.5 5.0 Setup instructions Accessing iServer units using the internetDiagnostics Pressure/Temp Adjustable ChartOption Retrieving Data from FlashHost Name Refer to .4, DNS 10 Access Control#4 RTC is not set and the Flash Card is not empty Configuration#1 RTC is not set and Flash Card is empty #2 RTC is set, and recording is in progressSensor/Device Setup 11 ConfigurationTHi/Lo BHi/Lo BHi/Hi BLo/Hi BLo/Lo Real Time ClockFlash Recording Terminal Server Remote Access Sensor Parameters T75.7F P1014.9mbarRemote End Char Httpget Program Telnet SetupResponse Httpget using PortHttpget and ARP to setup Device IP Address Apr -s 192.168.1.200 00-03-34-00-00-06-b6Httpget -r -S 00000000 Where ARP Protocol 14 ARP Commands and Responses15 iLOG Software Logging Data ILOG SoftwareMail Notifier Software InstallationEmail Connection Mapi Access 17 iServer Mail Notifier Profile Setup18 iServer Mail Notifier Device Setting Device Setting and Configuration Device setup requiresPackaging Part 5 SpecificationsTemperature T PowerNetwork Interface Remote Access TunnelingAppendix a Glossary Appendix B IP Address Class C Appendix C IP NetmaskMask Dotted Notation Mask Binary Mask Bits Class a Class BDec Hex Binary Char No Parity No parity Appendix D Ascii ChartAscii Dec Hex BinaryDec Hex Ctrl Key Definition Char Equiv Appendix D Ascii Chart ContinuationAscii Control Codes Dec Hex Ctrl Key DefinitionMeasurement Category Part Approvals Information CE ApprovalWARRANTY/DISCLAIMER Shop on line at omega.com