Omega Engineering i.BTX-M manual Device Setting and Configuration Device setup requires

Page 38

4.8.3Device Setting and Configuration Device setup requires:

• Entering the IP address for iServer device (for example 192.168.1.200).

• Specifying Socket number (1000 or 2000 depending on iServer settings).

Defining RS485 Unit # interface address (1 to 199). Enter "0" for RS232 interface or for iServer.

Entering Reading command. Normally set to SRT to obtain reading from the devices.If you want to change this setting, refer to HTTPget Section 4.5.

Defining the Alarm setup (High/Low, High value, or Low value).

Specifying Pause Interval. It determines how many seconds each subsequential alarm notification will be sent.

Determining Monitor interval. It establishes the interval or time resolution in seconds for which readings will be obtained from the device.

Figure 4.18 iServer Mail Notifier Device Setting

34

Image 38
Contents User’s Guide OMEGAnet On-Line Service Internet e-mail Info@omega.com Servicing North AmericaTable of Contents List of Figures IServer and iLD Big Display on the Ethernet NetworkFeatures Part Introduction Computer with Standard Web Browser Mounting DIP SwitchesPart 2 Hardware Parts of the iServer Unit Parts of the iServer Unit Parts of iServer UnitDisassembly Instruction Opening the UnitRunning on Battery Power 2 10Base-T Crossover WiringRelay Wiring Connections Network Communication Interfaces 1 10Base-T RJ-45 PinoutEthernet MAC Address Part Network ConfigurationNetwork Protocols Dhcp IP AddressExample C\Telnet 192.168.1.200 Default IP AddressPort Number Testing the Connection Part OperationsAssigning an IP Address using iCONNECT ICONNECT SoftwareSetting a New IP Address over the Network Access ControlSetup and Operation using the iServer Web IServer HomeRead Sensor Java Runtime Environment 1.4 Setup instructions Read SensorDiagnostics Java Runtime Environment 1.5 5.0 Setup instructionsAccessing iServer units using the internet Adjustable Chart Pressure/TempRetrieving Data from Flash Option10 Access Control Host Name Refer to .4, DNS#2 RTC is set, and recording is in progress Configuration#1 RTC is not set and Flash Card is empty #4 RTC is not set and the Flash Card is not empty11 Configuration Sensor/Device SetupReal Time Clock THi/Lo BHi/Lo BHi/Hi BLo/Hi BLo/LoFlash Recording Terminal Server Remote Access Remote End Char Sensor ParametersT75.7F P1014.9mbar Telnet Setup Httpget ProgramHttpget using Port ResponseHttpget -r -S 00000000 Where Httpget and ARP to setup Device IP AddressApr -s 192.168.1.200 00-03-34-00-00-06-b6 14 ARP Commands and Responses ARP ProtocolILOG Software 15 iLOG Software Logging DataInstallation Mail Notifier Software17 iServer Mail Notifier Profile Setup Email Connection Mapi AccessDevice Setting and Configuration Device setup requires 18 iServer Mail Notifier Device SettingPower Part 5 SpecificationsTemperature T PackagingRemote Access Tunneling Network InterfaceAppendix a Glossary Appendix B IP Address Class B Appendix C IP NetmaskMask Dotted Notation Mask Binary Mask Bits Class a Class CDec Hex Binary Appendix D Ascii ChartAscii Dec Hex Binary Char No Parity No parityDec Hex Ctrl Key Definition Appendix D Ascii Chart ContinuationAscii Control Codes Dec Hex Ctrl Key Definition Char EquivPart Approvals Information CE Approval Measurement CategoryWARRANTY/DISCLAIMER Shop on line at omega.com