CLASSIFICATION |
|
| No. |
|
| REV. |
Einstufung |
|
|
| C | ||
SUBJECT | EvalBoard PAN4570 | PAGE |
|
|
| |
Thema |
|
| Seite | 12 of 20 |
| |
CUSTOMER’S CODE |
| PANASONIC’S CODE | DATE | 06.11.2006 | ||
EvalPAN4570 |
|
| Datum |
Connect the Ember™ Insight Adaptor to the SIF connector on the module carrierboard with the grey ribbon cable supplied with the Insight Adaptor. Please make sure that pin1 of the plug connects to pin1 of the header.
5.Connect the Ember™ Insight Adaptor via a USB cable or crossover network cable
to the PC where EmberZNet™ is installed on. Start xIDE.
Within the menue TOOLS\AutoDetectSIF check >Add SIF Pods< and click>Next<. In the next window >Add new SIF Pod< click >Yes, search for new…<.
In the next window select your network adaptor and click >Next<. In the next window select the detected SIF pod and click >Next<. In the next window named >Configuration< click >Next<.
After the configuration the summary should be displayed:
Attempted to configure Ethernet Pod >address of Pod<
Found slave with no chip select.
Slave with no chip select is XAP2b
Within the menue TOOLS\Configure_SIF\SIF_configuration you can check for the pods and slave configuration.
6.On your pc create a new folder, for example C:\PAN4570
From the CD subfolder \software copy the following files to C:\PAN4570: em2xx_load.exe
(Instead of
The following DOS entries would start the programming of PAN4570 with “EmberTM Range Test Application 2.0” including the embedded bootloader :
>cd c:\PAN4570
em2xx_load.exe
For details on using the em2xx_load.exe utility see also [9]
European Technology Center
Panasonic Electronic Devices (EUROPE) GmbH
APPROVED
genehmigt
CHECKED
geprüft
DESIGNED
Erstellt