11
\ | Notes of safety |
|
|
|
| •\ | Do琀 not use batteries not specified for this unit. Do not insert the batteries with the polarities in | ||||||||
\ | Please read this instruction manual carefully before use and for further information on the | •\ | the wrong direction. | ||||||||||||
| individual functions. |
|
|
| Replace琀 | worn batteries with new ones immediately. | |||||||||
\ | Danger: |
|
|
|
|
|
|
| •\ | Remove琀 | the batteries from this unit when you are not going to use it for a long period of time | ||||
|
|
|
|
|
|
| •\ | (approximately three months or more). | |||||||
•\ | Never琀 | use this unit in combination with the following medical electronic devices. |
| Do琀 not use batteries of a different kind together. | |||||||||||
(1)\ Medical琀 | electronic implants such as pacemakers. |
| •\ | Do琀 not use new and worn batteries together. | |||||||||||
(2)\ Electronic琀 | life support systems such as an artificial heart/lung. |
| •\ | Keep琀 | this unit out of the reach of young children. | ||||||||||
(3)\ Portable琀 | electronic medical devices such as electrocardiograph. |
| \ | General Advice: | |||||||||||
•\ | This琀 | unit may cause the | |||||||||||||
| considerable health risk to users of these devices. |
| •\ | Do琀 not place this unit on cushioned floor surface such as on a carpet or a mat. Correct | |||||||||||
\ | Warning: |
|
|
|
|
|
| •\ | measurement may not be possible. | ||||||
|
|
|
|
|
| Do琀 not step on the operation buttons. Doing so may cause malfunction. | |||||||||
•\ | 琀Never start weight reduction or exercise therapy solely based on your own judgement. Be sure | •\ | Do琀 not place this unit in highly humid environment, where water may splash, under direct | ||||||||||||
•\ | to follow the instructions of a doctor or specialist. |
| •\ | sunshine, in a place where the air conditioner blows directly, or near fire. | |||||||||||
琀Do not use the unit on tiles or other surfaces that may be slippery, such as a wet floor. | Do琀 not use this unit for purposes other than measuring body weight and body fat percentage. | ||||||||||||||
•\ | 琀Do not subject the unit to strong shocks, such as vibrating or dropping the unit on the floor. | •\ | Disposal琀 | of this product and used batteries should be carried out in accordance with the | |||||||||||
•\ | 琀Do not jump or bounce on the unit. |
|
|
| •\ | national regulations for the disposal of electronic products. | |||||||||
•\ | 琀Do not use this unit after taking a bath, or when your body, hands, or feet are wet. |
| Always琀 | keep the unit clean before use. | |||||||||||
•\ | 琀Do not step on the edge of the unit. |
|
|
| •\ | Clean琀 | the scale before using the unit with people who have a skin or foot disease. | ||||||||
•\ | 琀Do not let a physically handicapped person use this unit without any accompanied assistance. | •\ | Do琀 not wash the unit with water. | ||||||||||||
| Use a handrail or so when stepping on the unit. |
| •\ | Do琀 not wipe the unit with benzene or paint thinner. | |||||||||||
\ | Caution: |
|
|
|
|
|
|
| •\ | When cleaning the unit, take care not to touch the buttons and change or delete the personal data. | |||||
|
|
|
|
|
|
| •\ | If琀 storing the unit in a vertical position, always secure it so that it will not fall over. | |||||||
•\ | 琀This unit is intended for home use only. It is not intended for professional use in hospitals or | •\ | Do琀 not store the unit in the following conditions: | ||||||||||||
•\ | other medical facilities. |
|
|
| \ | - Where water may get in. | |||||||||
琀This unit does not support the standards required for professional use. |
| \ | - Extreme high temperature and humidity, direct sunshine, and dusty places. | ||||||||||||
•\ | 琀Stand on the unit |
|
|
| \ | - Where there will be sudden shock or vibration. | |||||||||
•\ | 琀Do not use a cellular phone near the unit. |
|
|
| \ | - In storage places of chemicals or where corrosive gas is present. | |||||||||
•\ | 琀Do not disassemble, repair, or remodel the unit. |
| •\ | 琀Do not place objects on the unit or store it | |||||||||||
\ | Troubleshooting |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
| Error Display |
| Possible cause |
|
| Correction |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| You step off the unit during the measurement. |
| Do not step off the unit till the measurement is completed. | ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| Your feet are not correctly positioned on the electrodes. |
| Make sure that you are standing on the unit correctly and try again. | ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| The measurement position is not stable or your feet are not |
| Remain still and do not move during measurement. | ||||||
|
|
|
|
|
|
| placed correctly. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Feet are too dry. |
|
| Slightly moisten the soles of your feet with a damp towel and try again. | |||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| The unit is not set up correctly. |
| Remove the batteries. Wait one minute. Reinstall the batteries. Touch the | ||||||
|
|
|
|
|
|
|
|
|
| power. Retake the measurement. | |||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| You step onto the unit before 0.0 kg (0.0 lb) is displayed. |
| Wait until 0.0 kg (0.0 lb) is displayed before stepping onto the unit. | ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| The unit moved before 0.0 kg (0.0 lb) is displayed. |
| Do not move the unit until 0.0 kg (0.0 lb) is displayed | ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| Movement during measurement. |
| Do not move till measurement is completed. | ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| Your weight is over 150.0 kg (330.0 lb or 23 st 8.0 lb). |
| This unit can only be used by people weighing less than 150.0 kg (330.0 lb or 23 st 8.0 lb). | ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
Technical Data |
|
|
|
|
|
|
|
|
|
|
| ||||
Product description \ |
| Body Composition Monitor |
|
|
|
|
|
| |||||||
Product name\ |
|
|
| BF212 |
|
|
|
|
|
| |||||
Model \ |
|
|
|
|
|
|
|
|
|
|
|
| |||
Display\ |
|
|
|
|
|
| Body Weight: 2 to 150 kg with an increment of 0.1 kg / 4.4 to 330.0 lb with an increment of 0.2 lb / 4.4 lb to 23 st 8.0 lb with an increment of 0.2 lb | ||||||||
\ |
|
|
|
|
|
|
| Body Fat percentage: 5.0 to 60.0% with an increment of 0.1% |
|
|
|
|
| ||
\ |
|
|
|
|
|
|
| BMI: 7.0 to 90.0 with an increment of 0.1 |
|
|
|
|
|
| |
\ |
|
|
|
|
|
|
| BMI classification: - (Underweight) / 0 (Normal) / + (Overweight) / ++ (Obese) |
| ||||||
\ |
|
|
|
|
|
|
| • The age range for the BMI, BMI classification and Body Fat percentage is 10 to 80 years. | |||||||
Set Items Personal data information: \ | The following information for up to 4 people can be stored. |
|
|
|
|
| |||||||||
\ |
|
|
|
|
|
|
| Height: 100.0 to 199.5 cm , 3'4" to 6'6 3/4" (increment of 1/4") |
|
|
|
|
| ||
\ |
|
|
|
|
|
|
| Age: 10 to 80 years old |
|
|
|
|
|
| |
\ |
|
|
|
|
|
|
| Gender: Male/Female |
|
|
|
|
|
| |
Weight Accuracy \ |
| 2.0 kg to 40.0 kg: ± 0.4 kg, 40.0 kg to 150.0 kg: ± 1% / 4.4 lb to 88.2 lb: ± 0.88 lb, 88.2 lb to 330.0 lb: ± 1% / 4.4 lb to 6 st 4.2 lb: ± 0.88 lb, 6 st 4.2 lb to 23 st 8.0 lb: ± 1% | |||||||||||||
Accuracy (S.E.E.) \ |
| Body Fat percentage: 3.5% |
|
|
|
|
|
| |||||||
Power Supply \ |
|
|
| 4 AAA batteries (R03) (You may also use AAA alkaline batteries (LR03).) |
|
|
| ||||||||
Battery Life \ |
|
|
|
| Approximately one year (When AAA manganese batteries are used with four measurements a day at a room temperature of 23°C.) | ||||||||||
Operating Temperature/Humidity\ | +10°C to +40°C, 30 to 85 % RH |
|
|
|
|
|
| ||||||||
Storage Temperature/Humidity/Air Pressure\ |
|
|
|
|
| ||||||||||
Weight \ |
|
|
|
|
|
| Approximately 1.3 kg (including batteries) |
|
|
|
|
|
| ||
External Dimensions \ |
| Approximately 285 (W) × 28 (H) × 210 (D) mm |
|
|
|
|
|
| |||||||
Package Contents \ |
| Body composition monitor, 4 AAA manganese batteries (R03), instruction manual | |||||||||||||
Note: Subject to technical modification without prior notice. |
|
| Type BF | ||||||||||||
This device fulfills the provisions of the EC directive 93/42/EEC (Medical Device Directive). |
|
|
OMRON HEALTHCARE EUROPE B.V. guarantees this product for 3 years after date of purchase.
The guarantee does not cover battery, packaging and/or damages of any kind due to misusage (such as dropping or physical misuse) caused by the user. Claimed products will only be replaced when returned together with the original invoice / cash ticket.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the
This medical device manufactured by OMRON HEALTHCARE conforms to this
Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with
Correct Disposal of This Product(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life. To prevent pos- sible harm to the environment or human health from uncontrolled waste disposal, please separate this product from other types of wastes and recycle it responsibly to promote
the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can return this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
12