16 TROUBLESHOOTING

Problem

Probable Cause

 

Corrective Action

Page

 

Ref.

 

 

 

 

No signals are

1 The SQL control is fully clockwise.

1

Turn the SQL control counterclockwise.

19

received or receive

2 The Attenuator function is ON.

2

Press [ATT/PRE/ ANT1/2] until “ATT”

61

sensitivity seems

 

 

and “PRE” disappear.

 

poor.

3 Mic [PTT] is pressed.

3

Release Mic [PTT].

20

 

4 The IF filter bandwidth was

4

Review “DSP FILTERS”, “CHANGING

45,

 

incorrectly set.

 

THE IF FILTER BANDWIDTH” and set

46

 

 

 

the controls accordingly.

 

 

5 The wrong antenna connector

5

Press [ATT/PRE/ ANT1/2] (1 s) to

 

 

(ANT 1 or ANT 2) was selected.

 

select the other antenna connector.

60

 

6 The preamplifier is OFF.

6

Press [ATT/PRE/ ANT1/2] to switch

 

 

 

 

the function ON.

49

 

 

 

 

No signals are

The RF gain was set too low.

Press [MIC/ 5/ RF.G] (1 s) and turn the

18

received or receive

 

MULTI control clockwise to increase the

 

sensitivity seems

 

RF gain.

 

poor; S-meter is

 

 

 

 

reading full scale.

 

 

 

 

 

 

 

 

Received signals

The wrong modulation mode was

Press [MODE] or [MODE] (1 s) to select

19

are totally

selected.

the correct modulation mode.

 

unintelligible.

 

 

 

 

 

 

 

 

Memory Scan will

1 The SQL control was not set

1 Adjust the SQL control to just eliminate

19

not start scanning.

correctly.

 

background noise.

 

 

2 Less than 2 memory channels were

2 Unlock at least 2 memory channels.

54

 

unlocked.

 

 

 

 

3 Less than 2 memory channels were

3 Store data in at least 2 memory

50

 

programmed.

 

channels.

 

 

 

 

 

Memory Scan will

With Group Scan selected, the channel

Select the Memory Group that contains

59

not scan one of the

you want to scan is in a different group.

the memory channel you want to scan.

 

stored channels; the

 

 

 

 

desired channel is

 

 

 

 

NOT locked out.

 

 

 

 

 

 

 

 

Program Scan will

The start and end frequencies are

Store different start and end frequencies.

53

not start scanning.

identical.

 

 

 

 

 

 

 

AT does not finish

The impedance of the coaxial cable and

Adjust the antenna system to lower the

60

successfully

antenna was not matched.

SWR.

 

(TS-480SAT or

Tuning does not successfully finish

 

 

 

TS-480HX with

depending on conditions although the

 

 

 

AT-300).

SWR meter indicates smaller than 3:1.

 

 

 

 

 

 

 

The internal tuner is

The SWR of the antenna system is too

Adjust the antenna system to lower the

60

bypassed

high.

SWR.

 

immediately after

 

 

 

 

tuning is started.

 

 

 

 

 

 

 

 

 

You cannot transmit

1 The microphone plug was not

1

Turn OFF the power, ensure the MIC

6

even though you

inserted completely into the MIC

 

connector has no foreign objects in it,

 

press Mic [PTT] or

connector.

 

then plug in the connector firmly.

 

transmissions result

2 The Transmit Inhibit function is ON.

2

Change Menu No. 55 to OFF.

38

in no contacts.

3 CW or FSK was selected instead of

3

Press [MODE] to select a voice mode.

19

 

a voice mode.

 

 

 

 

4 The DSP TX filter bandwidth was

4

Adjust the settings in Menu No. 20.

38

 

inproperly selected.

 

 

 

 

5 The wrong antenna connector

5

Press [ATT/PRE/ ANT1/2] (1 s) to

60

 

(ANT 1 or ANT 2) was selected.

 

select the other antenna connector.

 

 

 

 

 

 

85

Image 93
Contents TS-480HX TS-480SAT Before Starting Supplied Accessories FeaturesQuantity Accessory Thank YOUMarket Codes Models Covered by this ManualWriting Conventions Followed Thank YOUPrecautions Contents Contents Optional Accessories TroubleshootingSpecifications IndexMobile Installation InstallationInstallation Example Remote Control Panel InstallationAntenna Connection Installation DC Power Cable ConnectionGround Connection Ignition NoiseDC Power Supply Connection Fixed Station InstallationInstallation TS-480SATAntenna Connection Ground ConnectionLightning Protection Fuses Portable Bracket E-TYPE onlyFuse Location Fuse Current Rating TS-480HX/ SATPanel and Microphone Connection Panel and Microphone Connection Using PG-4Z OptionAccessory Connections Remote Control PanelTX/ RX Unit Reception Your First QSOTransmission Your First QSOGetting Acquainted Remote Control Panel@3LED Getting Acquainted#0QMR/ MsVFO key @9QMI/ M.IN key#1A/B / M/V key #2A=B/ Split keyLCD Display 2AGC OFF5FINE @5DNL @4M.SCR@8AUTO #4RITEXT.SP jack TX/ RX UnitPaddle and KEY jacks Plastic coverCooling Fans GND postRemote Control Panel Rear MicrophoneUP/ DWN keys Adjusting Volume Switching Power ON/ OFFOperating Basics Selecting VFO a or VFO BAdjusting Squelch Selecting a ModeSelecting a Band Selecting a FrequencyWhat Is Measured? Selecting Transmission PowerMULTI-FUNCTION Meter TransmittingPress MIC/ 5/ RF.G Operating Basics Microphone GainWhat is a MENU? Menu SetupMenu Access Quick MenuMenu Configuration FunctionDSP Group Menu Function Selections Default Menu SetupTOT FSKAPO Function Menu Alphabetical Function ListBasic Communications SSB TransmissionFM Transmission Narrow Bandwidth for FM AM TransmissionNarrow Bandwidth for AM Basic CommunicationsCW Transmission Auto ZERO-BEATTX SIDETONE/ RX Pitch Frequency Enhanced Communications Press MENU/ F.LOCK 1 s to lock the Tuning controlSPLIT-FREQUENCY Operation TF-SET Transmission Frequency SETEnhanced Communications FM Repeater OperationTone FREQ. ID Scan Enhanced Communications Transmitting a ToneActivating the Tone Function Selecting a Tone FrequencyFM Ctcss Operation Ctcss FREQ. ID ScanFreq Communicating Aids ReceptionSelecting Your Frequency RIT Receive Incremental Tuning Communicating AidsAGC Automatic Gain Control VOX VOICE-OPERATED Transmit TransmissionCommunicating Aids Speech Processor XIT Transmit Incremental TuningCharacteristics Communicating Aids Customizing Transmission SignalTransmit Inhibit Busy LockoutAuto Weighting Using Semi BREAK-IN or Full BREAK-INCW BREAK-IN Electronic KeyerStoring CW Messages CW Message MemoryChecking CW Messages without Transmitting Transmitting CW MessagesMIC UP/ DWN KEY Paddle Mode Auto CW TX in SSB ModeFrequency Correction for CW Swap DOT and Dash Paddle PositionSpecialized Communications Radio Teletype RttyA./ Canada ARU Region Specialized Communications Packet RadioSlow Scan TV/ Facsimile Rejecting Interference Mode If filter bandwidthIf Filter Changing the if Filter BandwidthDSP Filters Adjust ModeRejecting Interference Changing the DSP Filter BandwidthNoise Blanker Rejecting Interference Beat Cancel SSB/ FM/ AMDigital Noise Limiter DNL Noise Reduction ALL ModesDSP Filter for Data Communication SSB/ FM DSP RX MonitorCenter PRE-AMPLIFIER AttenuatorCW Reverse Reception Memory Channels Memory FeaturesStoring Data in Memory Simplex ChannelsMemory Recall and Scroll Memory FeaturesSplit-Frequency Channels Memory RecallMemory Scroll Memory TransferMemory \ VFO Transfer Temporary Frequency ChangesStoring Frequency Ranges Confirming Start/ End FrequenciesChannel 00 ~ Channel 90 ~ Memory Channel Name Memory Channel LockoutProgrammable VFO Available alpha-numeric charactersStoring Into Quick Memory Quick MemoryRecalling Quick Memory Channels Temporary Frequency ChangesNormal Scan ScanVFO Scan Program ScanScan Program Scan Partially SlowedScan Hold Carrier-Operated mode co Time-Operated mode toMemory Scan Scan Resume MethodMemory Group Scan Group ScanScan Group Select Performing Group ScanOperator Conveniences AntennasAutomatic Antenna Tuner Presetting Auto ModeOperator Conveniences External Antenna Tuner typeMode Morse Code Output Beep FunctionBeeps What it means Display Linear Amplifier ControlLock Functions PF KEY Microphone PF KeysRX DSP Equalizer RX MonitorTX Power TIME-OUT TimerTransverter TX MonitorUsing Quick Transfer Setting UPTX Tune Quick Data TransferCommunication Parameters Computer ControlOptional Remote Controlling the TS-480 onOperator Conveniences Controlling the TS-480 from PC NetworkConstant Recording Operator Conveniences Message PlaybackLock MenuQMI/ M.IN ENTCrossband Repteater Voice Guide Announcement VolumeVoice Guide Announcement Speed OperationOperator Conveniences DX Packetcluster Tune SKY Command II Diagram Operator Conveniences SKY Command II K-TYPE onlyPreparation Control OperationUsing TH-D7A AS a Commander TH-D7A Commander SetupMic Key Function DWN PowerMode CLRCompatible Transceiver ComputerRtty Operation Connecting Peripheral EquipmentRemote terminal pin assignment 8-pin mini DIN Pin No FunctionData connector pin assignment 6-pin mini DIN Antenna TunerMCP and TNC Crossband Repeater DX Packetcluster TuneTM-D700A Connecting Peripheral Equipment SKY Command II K-TYPE onlyRemoving the TOP Cover Installing OptionsVGS-1 Voice Guide & Storage Unit YF-107C/ CN/ SN if Filters and SO-3 TcxoReference Frequency Calibration Installing OptionsTS-480 transceiver without SO-3 TS-480 transceiver with SO-3General Information TroubleshootingTroubleshooting TroubleshootingProblem Probable Cause Corrective Action Press MENU/ F.LOCK 1 s to switchPress Mode or Mode 1 s to select Press ATT/PRE/ ANT1/2 to switchPress ATT/PRE/ ANT1/2 until ATT Press ATT/PRE/ ANT1/2 1 s toFM Repeater Operation VGS ERR DC ErrorDemonstration Mode Microprocessor ResetInitial Settings Partial ResetOperation Notices DC Power SupplyFAN Noises Internal BeatsOptional Accessories PG-4ZVGS-1 F1B FSK SpecificationsReceiver SpecificationsCtcss IndexIndex RttyVFO