4-2 PLL ADJUSTMENT
ADJUSTMENT | ADJUSTMENT CONDITIONS |
| MEASUREMENT |
| VALUE | ADJUSTMENT | |||||
|
|
|
|
|
|
| |||||
UNIT |
| LOCATION | UNIT | ADJUST | |||||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
TX VCO LOCK | 1 | • LCD display | : A01 LW TXREF 127 | TX |
| Connect | the | digital | 4.0 V | TVCO | C17 |
VOLTAGE |
| • Transmitting |
|
|
| multi meter or oscillo- |
|
|
| ||
|
|
|
|
|
| scope to | check | point |
|
|
|
|
|
|
|
|
| CP4. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RX VCO LOCK | 1 | • LCD display | : A01 LW TXREF 127 | RX |
| Connect | the | digital | 4.0 V | RVCO | C17 |
VOLTAGE |
| • Receiving |
|
|
| multi meter or oscillo- |
|
|
| ||
|
|
|
|
|
| scope to | check | point |
|
|
|
|
|
|
|
|
| CP3. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
REFERENCE | 1 | • Wait for 5 minutes after power ON. | REAR |
| Loosely couple a fre- | 171.7250 MHz | FRONT | [PRT/BASE] | |||
FREQUENCY |
| • LCD display | : A01 LW TXREF | panel |
| quency counter to the | [GEN74] |
| /[MONI] | ||
|
| Connect the RF power meter or 50 Ω |
|
| [TX] antenna connec- | 173.7250 MHz |
|
| |||
|
| dummy load to the [TX] antenna con- |
|
| tor. |
|
| [Other] |
|
| |
|
| nector. |
|
|
|
|
|
|
|
|
|
|
| • Transmitting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 2 | • Push the [PROG] button | RX |
| Connect the frequency | 140.2750 MHz | FRONT | [PRT/BASE] | |||
|
| • LCD display | : A01 LW RXREF |
|
| counter to check point | [GEN74] |
| /[MONI] | ||
|
| • Receiving |
|
|
| CP2. |
|
| 142.2750 MHz |
|
|
|
|
|
|
|
|
|
|
| [Other] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
•IC-FR3000 TOP VIEW
TX UNIT
RX UNIT
• TX UNIT TOP VIEW | • RX UNIT TOP VIEW |
|
| CP2 | CP2 |
| Reference frequency |
|
| check point | L10 |
|
|
CP2
CP4 |
|
|
|
CP4 |
|
|
|
CP1 | CP18 | CP3 |
|
LV |
| ||
|
|
| |
CP4 |
|
|
|
TX VCO lock voltage |
|
|
|
check point |
| CP3 |
|
C17 (TVCO unit) |
| C17 (RVCO unit) | |
TX VCO lock voltage |
| RX VCO lock voltage | RX VCO lock voltage |
adjustment |
| chack point | adjustment |
4 - 5