Icom IC-FR3000 manual Ctcss, Dtcs

Page 23

SOFTWARE ADJUSTMENT – continued

Select an item using [CH-UP] / [CH-DN] buttons, then set specified value using [RPT/BASE] / [MONI] buttons on the

FRONT PANEL.

ADJUSTMENT

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

CTCSS

1 • LCD display : A10 LW CDCDEV

Rear

Connect the FM deviation meter

±0.65 kHz [Other]

DEVIATION

• Operating freq. : 160.2750

MHz [GEN74]

panel

to the [TX] antenna connector

±0.52 kHz [FRG2]

(WIDE)

162.2750

MHz [Other]

 

through the attenuator.

 

Set the FM deviation meter as:

HPF

: OFF

LPF

: 20 kHz

De-emphasis: OFF

Detector

: (P–P)/2

No audio applied to the [MIC] connector.

Transmitting

(NARROW)

2 • LCD display

: A12 LN CTCDEV

 

 

 

±0.35 kHz

 

 

• Operating freq : 160.2750

MHz [GEN74]

 

 

 

 

 

 

 

 

162.2750

MHz [Other]

 

 

 

 

 

 

 

• No audio applied to the [MIC] connector.

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DTCS

• LCD display

: A11 LW DTCADJ

Rear

Connect the FM deviation meter

 

 

 

 

Set to flat wave

 

MODULATION

• Operating freq. : 160.2750

MHz [GEN74]

panel

with an oscilloscope to the [TX]

form

 

BALANCE

 

162.2750

MHz [Other]

 

antenna connector through the

 

 

 

 

 

• No audio applied to the [MIC] connector.

 

attenuator.

 

 

 

 

 

• Transmitting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPEATER

1 • LCD display : A13 LW RPTAF

Rear

Connect the FM deviation meter

±3.0 kHz [Other]

DEVIATION

• Operating freq : 158.2750

MHz (RX)

panel

to the [TX] antenna connector

±2.4 kHz [FRG2]

(WIDE)

 

[GEN74]

 

through the attenuator.

 

 

160.2750

MHz (TX)

 

 

 

 

 

[GEN74]

 

 

 

 

160.2750

MHz (RX)

 

 

 

 

 

[Other]

 

 

 

 

162.2750

MHz (TX)

 

 

 

 

 

[Other]

 

 

 

Connect the standard signal generator to the RX antenna connector and set

 

as:

 

 

 

 

 

Level

: 1 mV* (–47 dBm)

 

 

Modulation

: 1 kHz

 

 

 

 

Deviation

: ±3 kHz

[Other]

 

 

 

: ±2.4 kHz

[FRG2]

 

 

• Transmitting

 

 

 

 

(NARROW)

2 • LCD display

: A14 LN RPTAF

±1.5 kHz

 

• Operating freq : 158.2750

MHz (RX)

 

 

 

 

[GEN74]

 

 

 

160.2750

MHz (TX)

 

 

 

 

[GEN74]

 

 

 

160.2750

MHz (RX)

 

 

 

 

[Other]

 

 

 

162.2750

MHz (TX)

 

 

 

 

[Other]

 

 

• Transmitting

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

 

4 - 8

Image 23
Contents IC-fr3000 iC-fr3 1 0 Repair Notes IntroductionOrdering Parts Table of Contents General SpecificationsPA Unit Board LayoutBottom view Logic UnitRX Unit TX Unit3 2ND if and Demodulator Circuits RX Unit Receiver CircuitsRF Circuit RX Unit 2 1ST Mixer and 1ST if Circuits RX UnitMIC Mute Transmitter CircuitsReceiver Mute Circuits Logic Unit Power Amplifier Circuit PA Unit Case of the 2/5TONE SignalsCase of the Dtmf Signals from Dialer IC Case of the Ctcss and Dtcs Signals From the CPUPLL Circuits Other Circuits Power Supply CircuitsExpander IC Logic Unit IC41 Port AllocationsExpander IC Logic Unit IC39 Expander IC Logic Unit IC405 D/A Converter IC TX Unit IC5 MCK DtcsiTEL BusyMIC Battery RXPreparation Required Test EquipmentProcess to the Permit Adjustment Mode Access Before Entering the Adjustment ModeAfter Finishing Adjustment Entering the Adjustment ModeOperating in the Adjustment Mode Exiting the Adjustment ModeNarrow Adjustment Mode CH ListExplanation of LCD Display in the Adjustment Mode WideCP4 PLL AdjustmentIC-FR3000 TOP View TX Unit TOP View RX Unit TOP View CP2Software Adjustment Deviation PowerOutput LOWDtcs CtcssREG Unit Section Parts ListLogic Unit Front UnitBridge Resistor ERJ12YJ390U ECEV1CA100SR ECEV1CA220SR Tantalum Teesva 1V 104M8L RX Unit Tantalum Teesva 1V 224M8L Rvco Unit TX Unit Tvco Unit PA Unit JACK1 Unit VR UnitChassis Unit JACK2 UnitOption Unit Installation Duplexer and isolater installation ISO Isolater DUP Duplexer Connection Example 1 Isolater ConnectionExample 2 Duplexer Connection Example 3 Duplexer and Isolater ConnectionMechanical Parts and Disassembly Front Unit REG Unit Rvco Unit Transistors and Fets SEMI-CONDUCTOR InformationDiodes Tvco Unit Rvco Unit Front Unit¡BOTTOM View Rvco Unit Tvco Unit VR UnitBoard Logic UnitGND TMUTE1 Txaf Tone TMUTE2 Patemp Rvswr Fwswr RX Unit RX Unit TX Unit TX Unit PA Unit PA Unit REG Unit JACK1 Unit REG UnitJACK2 Unit Block Diagram PA Unit Wiring Diagram Section Voltage Diagram Rvco Unit TX Unit PA Unit Unit Logic Unit Chassis Unit Icom New Zealand 32, Kamiminami, Hirano-ku, Osaka, 547-0003, Japan