INTRODUCTION |
| DANGER |
This service manual describes the latest service informa- tion for the
Model | Version | Symbol | Frequency range | AC supply | Power | |
| U.S.A. | USA |
| 100 | 50 [W] | |
|
|
|
| |||
| GEN2 | 150 | ||||
|
|
| ||||
|
|
|
|
| ||
General | GEN4 |
| 220 | 50 [W] | ||
|
| |||||
|
|
|
| |||
|
| GEN74 | 148 | |||
|
|
|
| |||
|
|
|
|
|
| |
Europe | EUR2 | 150 | 220 | 25 [W] | ||
|
| |||||
Germany | FRG2 | |||||
|
|
|
| |||
|
|
|
|
|
|
To upgrade quality, all electrical or mechanical parts and internal circuits are subject to change without notice or obligation.
USE ONLY the specified AC voltage described on the AC power socket. Other voltages may causes repeater damage or personal injury.
DO NOT expose the repeater to rain, snow or any liquids.
DO NOT reverse the polarities of the power supply when connecting the repeater.
DO NOT apply an RF signal of more than 20 dBm (100 mW) to the antenna connector. This could damage the repeater’s front end.
ORDERING PARTS
Be sure to include the following four points when ordering replacement parts:
1.
2.Component part number and name
3.Equipment model name and unit name
4.Quantity required
<SAMPLE ORDER>
1110003780 S.IC NJM2902V
8930056450 2368 |
Addresses are provided on the inside back cover for your convenience.
REPAIR NOTES
1.Make sure a problem is internal before disassembling the repeater.
2.DO NOT open the repeater until the repeater is discon- nected from its power source.
3.DO NOT force any of the variable components. Turn them slowly and smoothly.
4.DO NOT short any circuits or electronic parts. An insu- lated tuning tool MUST be used for all adjustments.
5.DO NOT keep power ON for a long time when the re- peater is defective.
6.DO NOT transmit power into a signal generator or a sweep generator.
7.ALWAYS connect a 40 dB or 50 dB attenuator be- tween the repeater and a deviation meter or spectrum analyser when using such test equipment.
8.READ the instructions of test equipment thoroughly before connecting equipment to the repeater.