Icom IC-F21GM instruction manual Battery Packs, ‘ Battery pack replacement

Page 12

3 BATTERY PACKS

Battery pack replacement

Before replacing the battery pack, the volume control MUST be ro- tated fully counterclockwise,

until a click is heard, to turn the

power OFF.

• Push the battery release for- ward, then pull the battery pack upward with the trans- ceiver facing you.

DBATTERY PACKS

Charging period

Battery

Voltage

Capacity

 

BC-144,

Operating

pack

 

 

BC-146

period*1

 

 

 

BC-119 or

 

 

 

 

 

BC-121

 

BP-208*2

Battery case for AA

 

 

 

(R6) 6 alkaline

 

 

 

BP-209

7.2 V

1100

12 hrs

1.5 hrs

8 hrs

mAh

 

 

 

 

 

BP-210

7.2 V

1650

18.5 hrs

2.0 hrs

11 hrs

mAh

 

 

 

 

 

BP-222*3

7.2 V

600

6.5 hrs

1 hr

5.5*3 hrs

mAh

 

 

 

 

 

*1 Operating periods are calculated under the following conditions; Tx : Rx : standby =5 : 5 : 90

*1 Operating period depends on the alkaline cells used. (BP-208 only)

*2 Output power is automatically reduced to 1 W to retain sufficient power in case of an emergency, etc.

*3 Operating period measured with the 2 W model.

5

Image 12
Contents IF21GM Safety Training Information Electromagnetic Interference/Compatibility General Mobile Radio Service Gmrs Page Foreword Table of Contents Speaker Volume Control OFF/VOL PTT Switch PTTAntenna Connector TX/RX Indicator LED p‘ LED indicator Accessories ‘ Accessory attachmentSupplied accessories AntennaBattery Packs ‘ Battery pack replacementBattery Packs ‘ Battery cautions Recycling information U.S.A. only‘ Battery charging Rapid charging with the BC-144+AD-99Check orientation and the spacer com- bination as follows Spacer combinationRapid charging with the BC-121+AD-94 #11 Regular charging with the BC-146Battery pack life ‘ Charging Note‘ Battery case Option SET Mode ‘ Set modeSetting the SIMPLEX/DUPLEX Operation Frequency channel list Rx/Tx FreqExample Ctcss tone code list FreqSetting the Ctcss Tone Frequency Push PTTExample Ctcss Find Operation ‘ Receiving and transmittingTIME-OUT Timer Power Save FunctionMonitor Audible Function Audible condition‘ Setting squelch level ‘ Auto scan function‘ Wide/Narrow selection Option ‘ OptionsCharger Other Options MB-74BELT ClipCount on us