OPERATION 5
‘Setting squelch level
The squelch circuit mutes the received audio signal depending on the signal strength. Scan proceeds in sequence from lower channel to higher channel numbers.
qWhile pushing [PTT] and [W/N], turn the transceiver’s power on
to enter the squelch adjustment mode.
wPush [MONI] to increase the squelch level (tight squelch) or [W/N] to decrease the squelch level (loose squelch).
•Squelch level will be fixed after 1 sec.
‘Auto scan function
Auto scan function proceeds in sequence from lower channel to higher channel numbers. Scanning searches for signals automati- cally and makes it easier to locate new stations for contact or lis- tening purpose.
qTurn the CH select knob to CH 16. Scan starts automatically.
•When receiving a signal, scan pauses until a signal disappears.
NOTE: You can perform the scan start/stop by optional
‘Wide/Narrow selection
You can easily to toggle between wide FM mode and narrow FM mode by pushing [W/N] key.
•Push [W/N]: Turns to wide FM mode.
•Pushing and holding [W/N]: Turns to narrow FM mode.
22