Icom IC-40S Specifications, DGeneral DTransmitter, DReceiver, Current drain approx

Page 22

9

 

SPECIFICATIONS

DGeneral

 

 

DTransmitter

 

 

• Frequency coverage

: 450.000–480.000 MHz

 

 

 

 

(Incl. all 40 UHF C.R.S. ch.)

• Output power

: Max. 5 W (at 9.6 V DC)

• Mode

: FM (16K0F3E)

 

• Modulation

: Variable reactance frequency

• Tuning step increment

: 25 kHz

 

 

modulation

• Acceptable power supply

: 9.6 V DC nominal

• Max. frequency deviation

: ±5 kHz

(negative ground)

(authorized battery packs)

• Spurious emissions

: 70 dB typical

• Usable temp. range

: –10˚C to +60˚C

 

• Adjacent channel power

: 70 dB typical

• Frequency stability

: ±5 ppm

 

• External mic. connector

: 3-conductor 2.5 (d) mm/2 k

• Current drain (approx.)

:

 

DReceiver

 

 

Tx

at 5 W

1.6 A

 

 

 

at 1 W

0.7 A

• Receive system

: Double conversion

Rx

standby

60 mA

 

superheterodyne

 

max. audio

250 mA

• Intermediate frequencies

: 1st

46.35 MHz

 

power saved

13 mA

 

2nd

450 kHz

• Antenna impedance

: 50 (nominal)

 

• Sensitivity

: 0.25 µV at 12 dB SINAD

• Dimensions

: 57(W) 140(H) 37(D) mm

• Squelch sensitivity

: 0.25 µV typical (at threshold)

(projections not incl.)

 

 

• Adjacent ch. selectivity

: 70 dB typical

• Weight (with BP-195)

: 370 g

 

• Spurious response

: 70 dB typical

 

 

 

• Intermodulation rejection

: 65 dB typical

 

 

 

• Audio output power

: 500 mW typical at 10%

 

 

 

(at 9.6 V DC)

distortion with an 8 load

 

 

 

• External SP connector

: 2-conductor 3.5 (d) mm/8

All stated specifications are subject to change without notice or obligation.

18

Image 22
Contents I40S N33 Supplied Accessories Accessories included with the transceiver QtyTable of Contents Antenna Accessory AttachmentBattery pack replacement Belt clipPanel Description Panel description1EXTERNAL DC Power Jack Charge Function display Basic Operation Select the desired channel with the Y/Z switchesPush LOW to select the output power if necessary Receiving and transmittingLock function DSetting the backlighting timerDisplay backlighting Monitor functionRepeater operation Push and hold PTT to transmitOpen scan Scan OperationScan types Open ScanGroup and priority scans Setting scan tagSelect the priority channel if desired Push LOW for 2 sec. to exit Set mode Scan resume ConditionTone Squelch Operation Calling a waiting station using pocket beepSquelch opens and the signal can be heard Tone squelch operation Pocket beep operationRapid charging with the BC-119 Battery PacksCharging Battery pack Precautions Tery pack becomes exhaustedMultiple charging with the BC-121 Regular chargingBattery pack life About the battery packInstalling batteries in the battery case Operating periodOther Functions Time-out timer Power saverConfirmation beeps Optional HM-75A functions Turning the microphone remote control function ON/OFFTransmit lockout HM-75A functionsTroubleshooting Problem Possible Cause SolutionDReceiver SpecificationsDGeneral DTransmitter Current drain approxOptions Battery packsOther options Kamihigashi, Hirano-ku, Osaka 547 Japan