Cisco Systems UCS C420 manual Installing the Server Service DIP Switch

Page 34

Chapter 2 Installing the Server

Service DIP Switch

Procedure 2: Use BIOS Recovery DIP Switch and recovery.cap File

Step 1 Download the BIOS update package and extract it to a temporary location.

Step 2 Copy the contents of the extracted recovery folder to the root directory a USB thumb drive. The recovery folder contains the recovery.cap file that is required in this procedure.

Note The recovery.cap file must be in the root directory of the USB thumb drive. Do not rename this file. The USB thumb drive must be formatted with either FAT16 or FAT32 file systems.

Step 3 Power off the server as described in Shutting Down and Powering Off the Server, page 3-8.Step 4 Disconnect all power cords from the power supplies.

Step 5 Slide the server out the front of the rack far enough so that you can remove the top cover. You might have to detach cables from the rear panel to provide clearance.

Caution If you cannot safely view and access the component, remove the server from the rack.

Step 6 Remove the top cover as described in Removing and Replacing the Server Top Cover, page 3-9.Step 7 Locate BIOS recovery DIP switch 2. See Figure 2-5.

Step 8 Use a small pointed object such as a screwdriver to move DIP switch 2 to the closed (upper) position. Step 9 Reconnect AC power cords to the server. The server powers up to standby power mode.

Step 10 Insert the USB thumb drive that you prepared in Step 2 into a USB port on the server. Step 11 Return the server to main power mode by pressing the Power button on the front panel.

The server boots with the updated BIOS boot block. When the BIOS detects a valid recovery.cap file on the USB thumb drive, it displays this message:

Found a valid recovery file...Transferring to CIMC

System would flash the BIOS image now...

System would restart with recovered image after a few seconds...

Step 12 Wait for server to complete the BIOS update, then remove the USB thumb drive from the server.

Note During the BIOS update, the CIMC will shut down the server and the screen will be blank for about 10 minutes. Do not unplug the power cords during this update. The CIMC will power on the server after the update is complete.

Step 13 After the server has fully booted, power off the server again and disconnect all power cords. Step 14 Move DIP switch 2 back to the default open (lower) position.

Note If you do not move the switch back to the default position, the CIMC attempts to recover the BIOS each time that you boot the server.

Step 15 Replace the top cover, replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button.

 

Cisco UCS C420 Server Installation and Service Guide

2-16

OL-27640-01

Image 34
Contents Cisco UCS C420 Server Installation and Service Guide Americas HeadquartersPage N T E N T S Special Considerations for Cisco UCS Virtual Interface Cards For More Information C-6 OL-24342-01 Organization AudienceChapter Title Description Conventions Bewaar Deze InstructiesAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança Guarde Estas Instrucciones GEM Disse Anvisninger Xii Xiii Related Documentation Documentation FeedbackOverview of the Cisco UCS C420 Server 2shows the rear panel features of the server 1lists the features of the server StandardCisco UCS C420 Server Features Installing the Server StatementServer Documentation Power cord up to two KVM cable Unpacking and Inspecting the ServerPreparing for Server Installation Installation GuidelinesRack Requirements Slide Rail Adjustment RangeEquipment Requirements Installing the Server In a Rack This section describes how to install the server in a rackInserting the Server into the Slide Rails Attaching the Cable Management Arm Connecting and Powering On the Server Standalone Mode Initial Server SetupThis section includes the following topics Installing the Server Initial Server Setup OL-27640-01 NIC Modes and NIC Redundancy Settings System Bios and Cimc Firmware Updating the Bios and Cimc FirmwareAccessing the System Bios Service DIP Switch DIP Switch Location on the I/O RiserUsing the Bios Recovery DIP Switch If These Steps do not Recover the BiosInstalling the Server Service DIP Switch Server Monitoring and Management Tools Server Configuration UtilityCisco Integrated Management Interface Status LEDs and Buttons Front-Panel LEDsLED Name State Rear-Panel LEDs and Buttons Rear-Panel LEDs and ButtonsRear-Panel LED States LED Name State Internal Diagnostic LEDs LED Name StateShutting Down and Powering Off the Server Preparing for Server Component InstallationRequired Equipment Removing and Replacing the Server Top Cover Release buttons Front cover panelReplaceable Component Locations See also -23 on page 3-40for detailsInstalling or Replacing Server Components Color-Coded Touch PointsReplacing Hard Drives or Solid State Drives Drive Population GuidelinesDrive Replacement Procedure Release button Drive tray securing screws Ejector leverReplacing a Modular Drive Bay Assembly Drive Bay Assembly and Transition Card Two VersionsOL-27640-01 Removing and Replacing the Drive-Bay Module Replacing Fan Modules FAN11 Removing and Replacing Fan Modules Replacing a Fan Tray 12 Removing and Replacing a Fan Tray Replacing DIMMs Dimm Performance Guidelines and Population RulesCPU Socket Color Black# of DIMMs Memory Mirroring Mode Dimm Replacement Procedure Replacing CPUs and Heatsinks CPU Replacement Procedure Open the hinged CPU cover plate. See Figure14 CPU Retaining Latches 16 Removing or Inserting a CPU Icon. See -14 on 18 Thermal Grease Application Pattern Replacing the Motherboard RTC Battery 19 Removing and Replacing the Motherboard RTC Battery Replacing a PCIe Riser Assembly 20 Removing and Replacing the PCIe Riser Assembly Replacing an I/O Riser 21 I/O Riser, Including SD Card SlotsRiser in designated motherboard socket Riser securing screw 22 Removing and Replacing an I/O RiserReplacing an Internal SD Card Replacing a PCIe Card PCIe SlotsNCSI3 Support Slot Number Lane Width Connector LengthElectrical Card Length1 Primary Slot Secondary Slot Alternate SlotsPCIe card socket on PCIe riser assembly Card retaining clip 24 PCIe Riser Assembly Side ViewReplacing a PCIe Card in a Motherboard Slot 25 Hinged PCIe Card Retainer on Rear of Chassis Supported Cisco Card NIC Server VICs Mode Firmware Integration Fabric InterconnectMinimum Firmware for Nexus OS on an Use With UCS Upstream NexusResolving Insufficient Memory Space to Execute Option ROMs Resolving Insufficient 16-Bit I/O Space 27 vNIC Properties Dialog Replacing the Supercap Power Module RAID Backup Unit 28 Removing the Scpm Installing a Trusted Platform Module 29 TPM Socket Location on Motherboard Set TXT Support to Enabled Replacing Power Supplies 30 Removing and Replacing Power SuppliesEnabling or Disabling the Internal USB Port OL-27640-01 Table A-1lists the physical specifications for the server Physical SpecificationsDescription Specification Environmental Specifications Power SpecificationsSupported Power Cords and Plugs Length Power Cord Description Feet MetersPower Cord, 250 VAC 13 a IEC60320 Plug North America Power Cord, 250 VAC 10 a CEI 23-16 Plug ItalyPower Cord, 250 VAC 10 a MP232 Plug Switzerland Power Cord, 250 VAC 13 a Nema 6-15 Plug North AmericaAC Power Cord Illustrations CAB-9K10A-AUCAB-9K10A-EU CAB-9K10A-SW CAB-N5K6A-NA Figure B-13 CAB-C13-CBN, Jumper Power Cord 0.68 m OL-24342-01 RAID Levels Supported RAID Controllers and Required CablesMaximum Optional Required Cables1 Controller Style Drives With expander3 Two controllers with two nonexpandersRAID Controller Cabling Supercap Power Modules RAID Backup UnitsMixing Drive Types in RAID Groups Mix of Drive Types RAID Group Allowed?334371 334646 334373 Foreign configurations found on adapter For More InformationPage OL-27640-01 Installation for Cisco UCS Integration OL-24342-01