Intel SC5300 BRP, SC5300 LX manual Additional Information and Software

Page 4

Preface

Additional Information and Software

If you need more information about this product or information about the accessories that can be used with this server chassis, use the following resources:

For in-depth technical information about this

Intel® Server Chassis SC5300 Technical Product

product, including BIOS settings and chipset

Specification at

information

http://support.intel.com/support/motherboards/server/chassis/

 

sc5300/sb/CS-012478.htm.

 

 

If you just received this product and need to

Intel® Server Chassis SC5300 Quick Start User’s Guide in

install it

the product box

 

 

For the latest product information

http://support.intel.com/support/motherboards/server/chassis/

 

SC5300

 

 

Spares and Accessories

http://support.intel.com/support/motherboards/server/sb/CS-

 

012636.htm

 

 

Server boards that are compatible with this

http://support.intel.com/support/motherboards/server/sb/CS-

chassis

012479.htm

 

 

For virtual system tours and interactive

http://developer.intel.com/design/servers/smarttool/index.htm

repair information

 

 

 

iv

Intel® Server Chassis SC5300 User Guide

Image 4
Contents Order Number C51486-003 Intel Server Chassis SC5300 User Guide Preface Manual OrganizationAdditional Information and Software Safety Information Safety Cautions Intel Server Chassis SC5300 User Guide Vii Wichtige Sicherheitshinweise 重要安全指导 Consignes de sécurité Instrucciones de seguridad importantes Xii Intel Server Chassis SC5300 User Guide Xiii Xiv Contents Equipment Log and Worksheets Figures Tables Feature Summary Kit ContentsChassis Description Chassis Front View SC5300 Base Intel Server Chassis SC5300 Base Front ViewChassis Front View SC5300 LX with Hot Swap Components Intel Server Chassis SC5300 LX Front ViewFront Panel Controls and Indicators Pedestal Controls and IndicatorsFront Panel LED Descriptions Base Chassis Rear View Intel Server Chassis SC5300 Base Chassis Rear ViewBase Redundant Power and SC5300 LX Chassis Rear View Peripherals Chassis Side ViewHalf-height Peripheral Bays Standard and Optional Hot Swap Drive BaysAccessories and Order Codes Accessories and Order CodesSetting Up the Chassis Installation Safety InstructionsSafety Before You Remove the Access Cover Tools and Supplies NeededSetting Up the Chassis Remove Primary Access Cover Removing the Access CoverRemove Bezel Assembly Removing Bezel AssemblyRemove Air Ducts Removing Air DuctsRemove Hot Swap Fans Removing Hot Swap FansRoute Power and Data Cables to the Fixed Drives Removing PCI Add-in Card RetainerRouting Power Cables to Fixed Drives Install 3.5-inch Floppy Drive Routing SCSI/SATA Data CablesInstalling Slides on 3.5-in Floppy Drive Install DVD or CD-ROM Drive Installing a DVD or CD-ROM DriveInstall Fixed Hard Drives Removing Six-drive Fixed Drive Cage from ChassisOpen the lower door Installing Device Slides to Hard Drive Close the lower door of drive cage Install Hot Swap Drives Releasing Drive Carrier from Hot Swap CageInstall Hot Swap Fans Inserting Drive Carrier into Drive CageInstall Server Board Install Air DamSecuring Cables in Chassis with a Hot Swap Power Supply Connect Cables to Server BoardInstall Add-in Boards Remove PCI Add-in Card RetainerPreparing the Chassis for a PCI Add-in Board Repeat until all PCI add-in cards are installed Reinstall the PCI Add-in Card Retainer Install Air Ducts Removing Inner Plastic Air Baffle from Processor Air DuctInstalling Air Ducts Install an Additional Hot Swap Power Supply Module Removing Power Supply Filler PanelInstall Bezel Assembly Pedestal Only Installing Bezel AssemblyInstall Primary Access Cover Installing the Access CoverSetting Up the Chassis Safety Before You Remove the Access Covers Maintaining Your ServerMaintaining Your Server Replacing a Fixed Fan For Base and BRP Chassis Only Removing a Fixed FanReplacing a Hot Swap Fan Removing a Hot Swap FanReplacing the Front Panel Board Removing the Front Panel BoardReplacing a Fixed Power Supply Installing the Front Panel BoardRemoving Fixed Power Supply Replacing a Hot Swap Power Supply Removing a Hot Swap Power SupplyReplacing a Power Distribution Board Removing Hot Swap Power SupplyRemoving Center Divider Removing Power Distribution Board Securing Power Distribution Board to Power Supply Cage Reinstalling Center Divider Removing Fixed Power Supply Releasing Center Divider from Power Supply Cage Removing Center Divider from Power Supply Cage Inserting Power Distribution Board in Power Supply Cage TP01997 Reinstalling Hot Swap Power Supply Maintaining Your Server Power Supply Specifications Single Power Supply Input VoltagesSingle Power Supply Output Voltages Technical Reference+3.3 24 a +5.0 +5 V Standby +12.0 48 a System Environmental Specifications Environmental SpecificationsEquipment Log and Worksheets Equipment LogEquipment Log Calculating Power Usage Current UsageWorksheet, Total Combined Power Used by the Server Product Safety Compliance Regulatory and Compliance InformationProduct Regulatory Compliance Product EMC Compliance Class a ComplianceCertifications / Registrations / Declarations Product Regulatory Compliance MarkingsElectromagnetic Compatibility Notices FCC USAIndustry Canada ICES-003 Europe CE Declaration of ConformityBsmi Taiwan Vcci JapanKorean RRL Compliance Regulated Specified Components Getting Help World Wide Web TelephoneMiami Limited Warranty for Intel Chassis Subassembly Products WarrantyExtent of Limited Warranty Warranty Limitations and Exclusions Limitations of LiabilityTelephone Support How to Obtain Warranty ServiceReturning a Defective Product