Intel SC5300 LX, SC5300 BRP Replacing a Fixed Power Supply, Installing the Front Panel Board

Page 62

Maintaining Your Server

4.Attach front panel cable (letter “A”) before installing the new Front Panel Board into the chassis to ensure the cable pins line up correctly. Place the new Front Panel Board in the chassis. Insert and tighten the three screws (letter “B”) removed earlier. Connect the optical switch cable (letter “C”) or, for rack-mount systems, reinstall the previously saved jumper.

A

B

C

TP00692

Figure 51. Installing the Front Panel Board

5.Replace the Bezel Assembly (see “Install Bezel Assembly” in Chapter 2 for step-by-step instructions).

6.Replace the Primary Access Cover (see “Install Primary Access Cover” in Chapter 2 for step- by-step instructions).

Replacing a Fixed Power Supply

WARNINGS

Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel.

1.Disconnect all power cables from chassis after shutting down the server.

2.Remove the Primary Access Cover (see “Remove Primary Access Cover” in Chapter 2 for step-by-step instructions).

3.Disconnect all internal power cables from chassis components and server board.

44

Intel® Server Chassis SC5300 User Guide

Image 62
Contents Order Number C51486-003 Intel Server Chassis SC5300 User Guide Preface Manual OrganizationAdditional Information and Software Safety Information Safety Cautions Intel Server Chassis SC5300 User Guide Vii Wichtige Sicherheitshinweise 重要安全指导 Consignes de sécurité Instrucciones de seguridad importantes Xii Intel Server Chassis SC5300 User Guide Xiii Xiv Contents Equipment Log and Worksheets Figures Tables Chassis Description Kit ContentsFeature Summary Chassis Front View SC5300 Base Intel Server Chassis SC5300 Base Front ViewChassis Front View SC5300 LX with Hot Swap Components Intel Server Chassis SC5300 LX Front ViewFront Panel Controls and Indicators Pedestal Controls and IndicatorsFront Panel LED Descriptions Base Chassis Rear View Intel Server Chassis SC5300 Base Chassis Rear ViewBase Redundant Power and SC5300 LX Chassis Rear View Half-height Peripheral Bays PeripheralsChassis Side View Standard and Optional Hot Swap Drive BaysAccessories and Order Codes Accessories and Order CodesSafety Before You Remove the Access Cover Setting Up the ChassisInstallation Safety Instructions Tools and Supplies NeededSetting Up the Chassis Remove Primary Access Cover Removing the Access CoverRemove Bezel Assembly Removing Bezel AssemblyRemove Air Ducts Removing Air DuctsRemove Hot Swap Fans Removing Hot Swap FansRoute Power and Data Cables to the Fixed Drives Removing PCI Add-in Card RetainerRouting Power Cables to Fixed Drives Install 3.5-inch Floppy Drive Routing SCSI/SATA Data CablesInstalling Slides on 3.5-in Floppy Drive Install DVD or CD-ROM Drive Installing a DVD or CD-ROM DriveInstall Fixed Hard Drives Removing Six-drive Fixed Drive Cage from ChassisOpen the lower door Installing Device Slides to Hard Drive Close the lower door of drive cage Install Hot Swap Drives Releasing Drive Carrier from Hot Swap CageInstall Hot Swap Fans Inserting Drive Carrier into Drive CageInstall Server Board Install Air DamSecuring Cables in Chassis with a Hot Swap Power Supply Connect Cables to Server BoardInstall Add-in Boards Remove PCI Add-in Card RetainerPreparing the Chassis for a PCI Add-in Board Repeat until all PCI add-in cards are installed Reinstall the PCI Add-in Card Retainer Install Air Ducts Removing Inner Plastic Air Baffle from Processor Air DuctInstalling Air Ducts Install an Additional Hot Swap Power Supply Module Removing Power Supply Filler PanelInstall Bezel Assembly Pedestal Only Installing Bezel AssemblyInstall Primary Access Cover Installing the Access CoverSetting Up the Chassis Safety Before You Remove the Access Covers Maintaining Your ServerMaintaining Your Server Replacing a Fixed Fan For Base and BRP Chassis Only Removing a Fixed FanReplacing a Hot Swap Fan Removing a Hot Swap FanReplacing the Front Panel Board Removing the Front Panel BoardReplacing a Fixed Power Supply Installing the Front Panel BoardRemoving Fixed Power Supply Replacing a Hot Swap Power Supply Removing a Hot Swap Power SupplyReplacing a Power Distribution Board Removing Hot Swap Power SupplyRemoving Center Divider Removing Power Distribution Board Securing Power Distribution Board to Power Supply Cage Reinstalling Center Divider Removing Fixed Power Supply Releasing Center Divider from Power Supply Cage Removing Center Divider from Power Supply Cage Inserting Power Distribution Board in Power Supply Cage TP01997 Reinstalling Hot Swap Power Supply Maintaining Your Server Single Power Supply Output Voltages Power Supply SpecificationsSingle Power Supply Input Voltages Technical Reference+3.3 24 a +5.0 +5 V Standby +12.0 48 a System Environmental Specifications Environmental SpecificationsEquipment Log and Worksheets Equipment LogEquipment Log Calculating Power Usage Current UsageWorksheet, Total Combined Power Used by the Server Product Regulatory Compliance Product Safety ComplianceRegulatory and Compliance Information Product EMC Compliance Class a ComplianceCertifications / Registrations / Declarations Product Regulatory Compliance MarkingsElectromagnetic Compatibility Notices FCC USAIndustry Canada ICES-003 Europe CE Declaration of ConformityKorean RRL Compliance Vcci JapanBsmi Taiwan Regulated Specified Components Getting Help World Wide Web TelephoneMiami Extent of Limited Warranty WarrantyLimited Warranty for Intel Chassis Subassembly Products Warranty Limitations and Exclusions Limitations of LiabilityReturning a Defective Product How to Obtain Warranty ServiceTelephone Support