Intel SC5300 LX Install Air Ducts, Removing Inner Plastic Air Baffle from Processor Air Duct

Page 51

Setting Up the Chassis

Install Air Ducts

1.If your system has two processors, remove the inner plastic air baffle from the inside of the Processor Air Duct.

NOTE

This step only applies to systems with two processors. If your server board has only one processor installed, leave the inner air baffle in place and proceed to Step 2.

TP00545

Figure 40. Removing Inner Plastic Air Baffle from Processor Air Duct

2.If you are installing an Intel® Server Board SE 7320SP2 or SE7525GP2, remove the outer plastic air baffle.

NOTE

Leave the outer air baffle in place if you are installing an Intel® Server

Board SE7520BD2 or SE7520AF2.

TP00700

Figure 41. Removing Outer Plastic Air Baffle from Processor Air Duct

Intel® Server Chassis SC5300 User Guide

33

Image 51
Contents Order Number C51486-003 Intel Server Chassis SC5300 User Guide Manual Organization PrefaceAdditional Information and Software Safety Information Safety Cautions Intel Server Chassis SC5300 User Guide Vii Wichtige Sicherheitshinweise 重要安全指导 Consignes de sécurité Instrucciones de seguridad importantes Xii Intel Server Chassis SC5300 User Guide Xiii Xiv Contents Equipment Log and Worksheets Figures Tables Kit Contents Feature SummaryChassis Description Intel Server Chassis SC5300 Base Front View Chassis Front View SC5300 BaseIntel Server Chassis SC5300 LX Front View Chassis Front View SC5300 LX with Hot Swap ComponentsPedestal Controls and Indicators Front Panel Controls and IndicatorsFront Panel LED Descriptions Intel Server Chassis SC5300 Base Chassis Rear View Base Chassis Rear ViewBase Redundant Power and SC5300 LX Chassis Rear View Standard and Optional Hot Swap Drive Bays PeripheralsChassis Side View Half-height Peripheral BaysAccessories and Order Codes Accessories and Order CodesTools and Supplies Needed Setting Up the ChassisInstallation Safety Instructions Safety Before You Remove the Access CoverSetting Up the Chassis Removing the Access Cover Remove Primary Access CoverRemoving Bezel Assembly Remove Bezel AssemblyRemoving Air Ducts Remove Air DuctsRemoving Hot Swap Fans Remove Hot Swap FansRemoving PCI Add-in Card Retainer Route Power and Data Cables to the Fixed DrivesRouting Power Cables to Fixed Drives Routing SCSI/SATA Data Cables Install 3.5-inch Floppy DriveInstalling Slides on 3.5-in Floppy Drive Installing a DVD or CD-ROM Drive Install DVD or CD-ROM DriveRemoving Six-drive Fixed Drive Cage from Chassis Install Fixed Hard DrivesOpen the lower door Installing Device Slides to Hard Drive Close the lower door of drive cage Releasing Drive Carrier from Hot Swap Cage Install Hot Swap DrivesInserting Drive Carrier into Drive Cage Install Hot Swap FansInstall Air Dam Install Server BoardConnect Cables to Server Board Securing Cables in Chassis with a Hot Swap Power SupplyRemove PCI Add-in Card Retainer Install Add-in Boards Preparing the Chassis for a PCI Add-in Board Repeat until all PCI add-in cards are installed Reinstall the PCI Add-in Card Retainer Removing Inner Plastic Air Baffle from Processor Air Duct Install Air DuctsInstalling Air Ducts Removing Power Supply Filler Panel Install an Additional Hot Swap Power Supply ModuleInstalling Bezel Assembly Install Bezel Assembly Pedestal OnlyInstalling the Access Cover Install Primary Access CoverSetting Up the Chassis Maintaining Your Server Safety Before You Remove the Access CoversMaintaining Your Server Removing a Fixed Fan Replacing a Fixed Fan For Base and BRP Chassis OnlyRemoving a Hot Swap Fan Replacing a Hot Swap FanRemoving the Front Panel Board Replacing the Front Panel BoardInstalling the Front Panel Board Replacing a Fixed Power SupplyRemoving Fixed Power Supply Removing a Hot Swap Power Supply Replacing a Hot Swap Power SupplyRemoving Hot Swap Power Supply Replacing a Power Distribution BoardRemoving Center Divider Removing Power Distribution Board Securing Power Distribution Board to Power Supply Cage Reinstalling Center Divider Removing Fixed Power Supply Releasing Center Divider from Power Supply Cage Removing Center Divider from Power Supply Cage Inserting Power Distribution Board in Power Supply Cage TP01997 Reinstalling Hot Swap Power Supply Maintaining Your Server Technical Reference Power Supply SpecificationsSingle Power Supply Input Voltages Single Power Supply Output Voltages+3.3 24 a +5.0 +5 V Standby +12.0 48 a Environmental Specifications System Environmental SpecificationsEquipment Log Equipment Log and WorksheetsEquipment Log Current Usage Calculating Power UsageWorksheet, Total Combined Power Used by the Server Product EMC Compliance Class a Compliance Product Safety ComplianceRegulatory and Compliance Information Product Regulatory ComplianceProduct Regulatory Compliance Markings Certifications / Registrations / DeclarationsFCC USA Electromagnetic Compatibility NoticesEurope CE Declaration of Conformity Industry Canada ICES-003Vcci Japan Bsmi TaiwanKorean RRL Compliance Regulated Specified Components World Wide Web Telephone Getting HelpMiami Warranty Limited Warranty for Intel Chassis Subassembly ProductsExtent of Limited Warranty Limitations of Liability Warranty Limitations and ExclusionsHow to Obtain Warranty Service Telephone SupportReturning a Defective Product