Furuno LS-6100 manual System & Installation Menus, System Menu, System menus

Page 25

2.SYSTEM & INSTALLATION MENUS

The System menu mainly consists of items which once set do not require frequent adjustment. You may display this menu by choosing SYSTEM MENU at page 2 of the menu and pressing ►.

PAGE 1

 

 

SYSTEM MENU

 

 

 

 

 

 

 

 

English

 

 

 

 

LANGUAGE

 

 

 

 

 

 

 

DEPTH UNIT

 

: ft

 

 

 

 

SPEED UNIT

 

: kt

 

 

 

 

WIND UNIT

 

: m/s

 

 

 

 

TEMP UNIT

 

: ° F

 

 

 

 

TEMP GRAPH

 

: Off

 

 

 

 

NAV DATA-1

 

:

 

 

 

 

 

 

 

NAV DATA-2

 

:

 

 

 

 

 

 

 

KEY BEEP

 

: On

 

 

 

 

BATT VOLTAGE

 

: Off

 

 

 

 

 

(1/3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MENU]: Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page no.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 2

 

 

SYSTEM MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NAV DISPLAY

 

 

Temp/Speed

 

 

 

 

 

 

 

 

 

NMEA0183

 

 

: Ver 2.0

 

 

 

 

TLL OUTPUT

 

: Off

 

 

 

 

BEARING

 

: True

 

 

 

 

WIND SPD/DIR

 

: Apparent

 

 

 

 

TRIP SOURCE

 

: Own

 

 

 

 

TEMP SOURCE

 

: Own

 

 

 

 

SPEED SOURCE : Own

 

 

 

 

 

 

 

 

TEMP CALIB.

 

: +0.0° F ( 40)

 

 

 

 

SPEED CALIB.

 

: +0% (±50)

 

 

 

 

 

Own speed

 

Own temp

 

 

 

 

 

 

 

 

 

10.0 kt

 

16.2° F

(2/3)

 

 

 

 

 

 

 

 

 

 

 

 

[MENU]: Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 3

 

SYSTEM MENU

 

 

 

 

BASIC RANGE1

 

15 ft

 

 

 

 

 

 

 

 

 

 

RANGE2:

30

 

 

 

 

 

 

 

 

RANGE3:

60

 

 

 

 

 

 

 

 

RANGE4:

120

 

 

 

 

 

 

 

 

RANGE5:

200

 

 

 

 

 

 

 

 

RANGE6:

400

 

 

 

 

 

 

 

 

RANGE7:

600

 

 

 

 

 

 

 

 

RANGE8: 1000 (7-1500)

 

 

 

 

 

 

 

 

 

ZOOM RANGE

:

15 ft (7-150)

 

 

 

 

B/L

RANGE

:

15 ft (10-30)

 

 

 

 

(Bottom Lock)

 

 

 

 

 

 

 

 

 

ZOOM MARKER: On

 

 

 

 

(3/3)

 

 

 

 

 

 

 

 

 

 

 

 

[MENU]: Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System menus

2.1 System Menu

Page 1

LANGUAGE: The system language is available in English, several European languages and Japanese. To change language, select language desired and press the [MENU/ESC] key.

DEPTH UNIT: Choose unit of depth measurement from meters, feet, fathoms, passi/braza and hiro (Japanese).

SPEED UNIT: Choose unit of speed measurement from knots, miles per hour and kilometers per hour. Requires speed data.

WIND UNIT: Choose unit of wind speed measurement from m/s, kt, km/h, and mph. Requires wind speed data.

TEMP UNIT: Choose unit of temperature measurement; Celsius or Fahrenheit. Requires temperature data.

TEMP GRAPH: Turns the water temperature display on or off. The temperature scale range is 16° (°F) in “Narrow”; 40° (°F) in “Wide”. Requires water temperature data.

 

50k

1/1

 

 

0.0

00

 

 

63.8° F

 

 

 

16.2kt

 

 

 

80

20

 

 

 

 

Temperature

70

 

Temperature

 

 

Scale

60

40

Graph

 

 

50

60

 

 

 

 

 

40

 

 

 

52.6 m

80

 

Water temperature display (wide, °F)

18

Image 25
Contents Echo Sounder 00080926502 Table of Contents Do not open the equipment Use the proper gain settingDo not disassemble or modify the equipment Use the proper fuseUse the specified power cable Safety Instructions for the InstallerForeword FeaturesWord to LS-6100 Owners IiiSystem Overview System configuration Equipment listsStandard supply Name Type Code No Qty Remarks Optional equipment Name Type Code No Qty RemarksHow to remove the hard cover Turning the Power On/OffOperation Control DescriptionBrilliance/contrast adjustment window Adjusting Display Contrast, BrillianceMode selection window Choosing a Display, FrequencyDual frequency display Single frequency displayMarker-zoom display Bottom-lock display Bottom-zoom displayNav data displays Bottom-zoom displayAutomatic Operation Menu Operating ProcedureHow automatic operation works Choosing automatic operationManual Operation Choosing the manual modeRange offset Gain offsetChoosing Picture Advance Speed Adjusting the gainUnit Basic Range Shifting the rangeScope Display Measuring DepthSuppressing Low Level Noise Suppressing InterferenceClutter appearance Forms of interferenceWhite Line Erasing Weak EchoesWaypoints 49.6Registering waypoint from the waypoint list Setting destination waypointProg Key Using the Prog keyEditing waypoints Erasing waypointsAlarm description AlarmsActivating an alarm Picture Color HueAlarm menu Depth, temperature, speed setting windowAlarm options Fish level optionsResetting Trip Distance Setting the DraftHow the alarm works Gain CompensationNAV Data Setup window Setting Up Nav Data DisplaysNav data window and item displayable 130 00.574E 30 00.065NNav data displays Water temperature display wide, F System & Installation MenusSystem Menu System menusNav window water temperature and speed Installation menu Installation MenuBottom level display Clear memory displayWaas options window MAINTENANCE, Troubleshooting Diagnostics TroubleshootingTroubleshooting table If… Then check …Test patterns Test PatternDisplay Unit InstallationThru-hull Mount Transducer Typical thru-hull mount transducer installations Thru-hull mount transducer mounting Dimensions millimetersAcceptable transducer mounting locations Suitable transducer mounting locationsConstruction of fairing block Transom Mount TransducerTransom mount transducer Mounting locations Transom mount transducer TapeInside-hull Transducer Optional Triducer Pre-test for speed and temperatureFinal preparation Tools and materials neededHeight required at mounting location Installation of bracketMounting location on single drive boat Positioning the template10 11 transom angle Transom AdjustingAngle Shim with Taper down Taper up Parallel Transom angleAttaching the sensor to the bracket Attaching the sensor to the bracketCable routing Wiring Optional Water Temperature/Speed SensorWater temperature/speed sensor Establishing the groundPin arrangement on Nmea port Optional equipmentWater temp/speed sensor Connection of converterWind sensor IEC 61162-1 Data SentencesFeeding data to RD-30 via the LS-6100 Specifications of the Echo Sounder LS-6100 Page