Table
Unit |
|
|
| Basic Range |
|
| |||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||
| |||||||||
meters | 5 | 10 | 20 | 40 | 80 | 150 | 200 | 300 | |
feet | 15 | 30 | 60 | 120 | 200 | 400 | 600 | 1000 | |
fathoms | 3 | 5 | 10 | 20 | 40 | 80 | 120 | 200 | |
P/B | 3 | 5 | 10 | 30 | 50 | 100 | 150 | 200 |
1.Press the [+] or
2.Press the [+] or
1000ft
600ft
400ft
200ft
120ft
60ft
30ft
15ft
Basic ranges (default)
Shifting the range
The basic range may be shifted up or down in the manual mode as follows:
1.Press the [MENU/ESC] key to open the menu.
2.Choose SHIFT from page 1 of the menu.
3.Press ► to open the shift options window.
Adjusting the gain
The [GAIN] key adjusts the sensitivity of the receiver. Generally, use a higher gain setting for greater depths and a lower setting for shallower waters.
Gain too high Gain proper Gain too low
Examples of proper and improper gain
1.Press the [GAIN] key and the display shown below appears.
GAIN
Min Max
|
|
|
|
|
|
200k |
|
|
| 2 | |
|
|
|
|
|
|
50k |
|
|
| ||
|
| 3 | |||
|
|
|
|
|
|
Gain adjustment window
2.When using the dual frequency display, press ▲ or ▼ to choose frequency.
3.Press the [GAIN] key to set. (You may also use ◄ or ►.) Adjust so that a slight amount of noise remains on the screen.
4.Press the [MENU/ESC] key to close the gain adjustment window.
0ft
Shift window
4.Use ▲ or ▼ to choose amount of shift desired.
5.Press the [MENU/ESC] key to close the menu.
Note: The picture may not be displayed if the amount of shift is greater than actual depth.
1.8Choosing Picture Advance Speed
The picture advance speed determines how quickly the vertical scan lines run across the screen. When choosing a picture advance speed, keep in mind that a fast advance speed will expand the size of the fish school horizontally on the screen and a slow advance speed will contract it. Note that the picture is not refreshed when picture advancement is stopped. Therefore, use caution when steering the vessel under this condition.
7