3.Press the [MODE] key to choose
SINGLE FREQ.
4.Choose 50 kHz or 200 kHz, and then press the [MENU/ESC] key to close the mode menu.
5.Press the [MENU] to show the main menu, and then press ▲ to select Auto mode.
6.Press ► ▲ to choose Off.
7.Press the [MENU/ESC] key.
8.Press the [GAIN] key to set the gain to “5” and then press the [MENU/ESC] key.
9.Press the [RANGE] key to set the range to 10 meters (feet) and then press the [MENU/ESC] key.
10.If the bottom is displayed in dark gray and the depth indication appears, the mounting location is suitable. Go to “Final preparation.”
11.If the bottom is not displayed in dark gray tone, the mounting location may be unsuitable. Do the following:
a)Press the [POWER/BRILL] key to turn off the power.
b)Gently dismount the transducer with a piece of wood.
c)Reattach the transducer elsewhere as shown in “Attaching the transducer.”
d)Check the installation again.
Final preparation
Support the transducer with a piece of wood to keep it in place while it is drying. Let the transducer dry
4.5 Optional Triducer
525ST-MSD
The optional triducer
φ79 mm
133 mm
threads7 mm φ 51 mm
27 mm | 140 mm |
Triducer 525ST-MSD
525ST-PWD
The Transom Mount Transducer or TRIDUCER® Multisensor with Integral Release Bracket
Pre-test for speed and temperature
Connect the sensor to the instrument and spin the paddlewheel. Check for a speed reading and the approximate air temperature. If there is no reading, return the sensor to your place of purchase.
Tools and materials needed
Scissors Masking tape Safety goggles Dust mask Electric drill Drill bit for:
Bracket holes: 4mm, #23, or 9/64”
Fiberglass hull: chamfer bit (preferred),
6mm, or 1/4”