3.7 Confirming Magnetron Heater Voltage
Magnetron heater voltage is adjusted at the factory. Confirm that magnetron heater voltage is within the prescribed rating as follows:
1. Turn on the radar and select the 0.125 mile range.
2. | Press [RADAR MENU] [0] [0] [0] [2] [0] to |
| open the INITIAL SETTING2 menu. |
3. | Press [5] to select the 5. SCANNER |
ANTENNA switch
ON
OFF
PM
| STOPPED field and the TX option. |
4. | Turn off the antenna switch in the display |
| unit. |
5. | Connect a multimeter, set to the 10 VDC |
| range, between #12(+) of P801 and the |
| chassis. |
ANTENNA
TUNE
6.The multimeter should read
7.“Transmit” on the 48 mile range.
8.The multimeter should read
DEGAUSS ERROR
Figure 3-5 Antenna switch in tuning compartment
9.Press [RADAR MENU] [0] [0] [0] [2] [0] [5]
to select the 5. SCANNER STOPPED field and the ROTATE option.
10.Turn on the ANT MOTOR SW on the scanner unit.