Furuno FR-2135S manual Heading Alignment, Picture appears Deviated counterclockwise

Page 38

3.4 Heading Alignment

You have mounted the scanner unit facing straight ahead in the direction of the bow. Therefore, a small but conspicuous target dead ahead visually should ap- pear on the heading line (zero degrees).

In practice, you will probably observe some small bearing error on the display because of the difficulty in achieving accurate initial positioning of the scanner unit. The following adjustment will compensate for this error.

Correct bearing

a

Apparent position

b

relative to heading

 

of target

 

a

Target

320

350

000

010

040

b

Target

 

 

340

020

 

 

 

 

330

 

 

 

030

 

 

 

 

310

 

 

 

050

 

 

 

 

300

 

 

 

060

 

 

 

 

290

 

 

 

070

 

 

 

 

280

 

 

 

080

Apparent

 

 

 

260

 

 

 

100

 

 

 

270

 

 

 

090

 

 

 

 

250

 

 

 

110

position

 

 

 

240

 

 

 

120

of target

 

 

 

230

 

 

 

130

 

 

 

220

 

 

 

140

 

 

 

 

210

 

 

 

150

 

 

 

 

200

190

180

170

160

 

 

Scanner mounted

Picture appears

Scanner mounted

error to port

deviated clockwise.

error to starboard

(HDG SW advanced)

 

(HDG SW delayed)

340

350

000

010

020

 

330

 

 

 

030

 

320

 

 

 

040

 

310

 

 

 

050

 

300

 

 

 

060

 

290

 

 

 

070

 

280

 

 

 

080

 

270

 

 

 

090

Correct

260

 

 

 

100

250

 

 

 

110

bearing

240

 

 

 

120

relative to

230

 

 

 

130

220

 

 

 

140

 

 

 

heading

210

 

 

 

150

200

190

180

170

160

Picture appears

deviated counterclockwise.

Figure 3-2 Heading alignment

1.Turn on the power. Press [RADAR MENU] [0] [0] [0] [2] [2] to select HL ALIGN on the INITIAL SETTING1 menu.

2.Select a target echo (by gyrocompass, for example) at a range between 0.125 and 0.25 nm, preferably near the heading line.

3.Operate the EBL control to bisect the target echo with the heading line. (The value shown on the display is scanner position in relation to ship's bow.)

4.Press [ENTER] to finish.

3-2

Image 38
Contents Back 00080839301 Safety Instructions Use only the specified power cable Table of Contents Equipment Lists Standard SupplyOptional Equipment Name Type Code No Qty RemarksSystem Configuration Scanner Unit Mounting considerationsInstallation precaution for S-band scanner unit ExampleHow to lift scanner unit Attachment of lifting fixtures and collarScanner unit assembling procedure Scanner unit assemblingInstallation of reinforcement ribs Fastening the scanner unit to the mounting platformMounting of scanner unit Before mounting the display unit Mounting procedureDisplay Unit Tabletop mountingStay 10 Setting catch to hole in stay Console type mounting Separating the control headDisplay unit modification procedure Separate type control head kit Type OP03-151, No14 Detaching the control head Control head modification procedure Connection of display unit to control head16 How to attach KB fixing plate Attachment of hoodPower Supply Unit This page is intentionally left blank Wiring Fabricating the power cable DPYCY-3.5 JIS cableCable fed from back of display unit default method Leading in cables to the display unitCable fed from outside display unit Cables fed from bottom of display unit console mountConnections RemoveConnectors on the INT Board Connectors on the INT BoardHow to attach NH connector HOW to Attach NH Connector to Signal Cable10 Scanner unit, port side view Fabricating signal cable S03-74 11 Fabricating the signal cable S03-7413 Scanner unit, rear view 15 Fabrication of coaxial cable Changing AC Power Specification of Display Unit When the de-icer is installed18 Power supply unit PSU-004 Adjusting Video Signal Level Tuning InitializationAccessing Menus for Initialization and Adjustment Restoring default settingsHeading Alignment Picture appears Deviated counterclockwiseAdjusting Sweep Timing Suppressing Main BangAntenna switch in tuning compartment Confirming Magnetron Heater VoltageInitial Setting Menus Scanner unit, stern side viewInitial SETTING1 menu Press Radar Menu 0 0 0Initial SETTING2 menu Initial SETTING3 menuInitial SETTING4 menu OWN Ship Information menuInstallation and connection of the Gyro Converter Board Gyro Converter GC-8INT Board Default setting Connection of external power supplyDIP switch, jumper wire settings Setting method 1 by gyrocompass specifications Gyrocompass typeSetting method 2 by make and model of gyrocompass JP1 JP2 JP3 JP4 JP5Setting the heading readout on the radar display SW1Installation of the ARP board ARP Board ARP-26ARP board adjustment ARP Board 18P9002BFinal check ARP Board ARP-26RP Board RP-26 Table top/console type10 Display pedestal Separate type control head Necessary parts RP-26-Z-2E Code no13 Display pedestal, front view Performance Monitor PM-50 Necessary parts PM-50 and OP03-150 Code noNecessary parts OP03-156 Code no Alarm KitProcedure 16 Display unit, inside view Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page