Furuno FR-2135S manual Attachment of hood, How to attach KB fixing plate

Page 22

Connection of display unit to control head

1.Attach the handle to the handle plate, using the screws for the handle and bottom cover of the control head.

2.Attach the handle plate to location where the KB arms were fastened.

3.Pull the monitor toward you until you hear click.

4.Lead in the cable assy. (option) from the rear entrance of the display unit. See Chapter 2.

5.Raise the monitor and fix the stay.

6.Inside the display unit, fasten ground wire of the cable assembly with an M4 screw on the chassis.

7.Plug in two connectors of connection cable (P412, J583: See illustration on the previous page.)

8.Lower the monitor.

9.Attach the monitor front cover (option) to the place the panel cover have been, using the screw for the panel cover.

10.Attach rubber to feet to the bottom of the keyboard if the keyboard is not going to be permanently fixed. To fix the keyboard to a desired location, fasten the KB fixing plate to the keyboard and desired location with two upset screws (M5X25, formerly used to fasten KB arms) and two tapping screws (φ 6.5, local supply) as below.

KB Fixing Plate

CONTROL HEAD

φ 6.5

SIDE VIEW

Tapping

 

 

Screw

KB Fixing

M5X25

Plate

CONTROL HEAD TOP VIEW

Upset

 

Screw

Tuning compartment (Performance Monitor SW inside)

Figure 1-16 How to attach KB fixing plate

11.Set dust cover KB (supplied) on the control head.

Attachment of hood

1.Set two spacers (supplied) to the lower two of the four M5 holes in the CRT panel.

2.Screw two screws (supplied) into the holes in the hood.

3.Set the bottom of the hood to the screws at the bottom of the CRT panel, and then fasten the two screws at the top of the hood to the CRT panel.

1-14

Image 22
Contents Back 00080839301 Safety Instructions Use only the specified power cable Table of Contents Equipment Lists Standard SupplyOptional Equipment Name Type Code No Qty RemarksSystem Configuration Scanner Unit Mounting considerationsInstallation precaution for S-band scanner unit ExampleHow to lift scanner unit Attachment of lifting fixtures and collarScanner unit assembling procedure Scanner unit assemblingInstallation of reinforcement ribs Fastening the scanner unit to the mounting platformMounting of scanner unit Before mounting the display unit Mounting procedureDisplay Unit Tabletop mountingStay 10 Setting catch to hole in stay Console type mounting Separating the control headDisplay unit modification procedure Separate type control head kit Type OP03-151, No14 Detaching the control head Control head modification procedure Connection of display unit to control head16 How to attach KB fixing plate Attachment of hoodPower Supply Unit This page is intentionally left blank Wiring Fabricating the power cable DPYCY-3.5 JIS cableCable fed from back of display unit default method Leading in cables to the display unitCable fed from outside display unit Cables fed from bottom of display unit console mountConnections RemoveConnectors on the INT Board Connectors on the INT BoardHow to attach NH connector HOW to Attach NH Connector to Signal Cable10 Scanner unit, port side view Fabricating signal cable S03-74 11 Fabricating the signal cable S03-7413 Scanner unit, rear view 15 Fabrication of coaxial cable Changing AC Power Specification of Display Unit When the de-icer is installed18 Power supply unit PSU-004 Adjusting Video Signal Level Tuning InitializationAccessing Menus for Initialization and Adjustment Restoring default settingsHeading Alignment Picture appears Deviated counterclockwiseAdjusting Sweep Timing Suppressing Main BangAntenna switch in tuning compartment Confirming Magnetron Heater VoltageInitial Setting Menus Scanner unit, stern side viewInitial SETTING1 menu Press Radar Menu 0 0 0Initial SETTING2 menu Initial SETTING3 menuInitial SETTING4 menu OWN Ship Information menuInstallation and connection of the Gyro Converter Board Gyro Converter GC-8INT Board DIP switch, jumper wire settings Connection of external power supplyDefault setting Setting method 1 by gyrocompass specifications Gyrocompass typeSetting method 2 by make and model of gyrocompass JP1 JP2 JP3 JP4 JP5Setting the heading readout on the radar display SW1Installation of the ARP board ARP Board ARP-26ARP board adjustment ARP Board 18P9002BFinal check ARP Board ARP-26RP Board RP-26 Table top/console type10 Display pedestal Separate type control head Necessary parts RP-26-Z-2E Code no13 Display pedestal, front view Performance Monitor PM-50 Necessary parts PM-50 and OP03-150 Code noProcedure Alarm KitNecessary parts OP03-156 Code no 16 Display unit, inside view Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page