The table below shows the ports and corresponding items to be set.

Port and data format/data transmission rate

Port

External device (MODE)

Format/Rate (SPEED)

COM1

LONG RANGE

IEC61162-1, IEC61162-2

EXT DISPLAY

IEC61162-1, IEC61162-2

 

DISABLE

-

 

EXT DISPLAY

IEC61162-1, IEC61162-2

 

MONITOR

IEC61162-1 (No use)

COM2

 

IEC61162-2

HI LEVEL IF

IEC61162-1 (No use)

 

 

 

IEC61162-2

 

DISABLE

-

 

EXT DISPLAY

IEC61162-1, IEC61162-2

 

MONITOR

IEC61162-1 (No use)

COM3

 

IEC61162-2

HI LEVEL IF

IEC61162-1 (No use)

 

 

 

IEC61162-2

 

DISABLE

-

COM4

SENSOR

IEC61162-1, IEC61162-2

EXT DISPLAY

IEC61162-1, IEC61162-2

 

DISABLE

-

COM5

SENSOR

IEC61162-1, IEC61162-2

COM6

SENSOR

IEC61162-1, IEC61162-2

 

AD-10

 

 

 

STANDARD

4800bps, 9600bps

 

 

19.2kbps, 38.4kbps, 57.6kbps

 

MONITOR

4800bps, 9600bps

PC

 

19.2kbps, 38.4kbps, 57.6kbps

SERVICE

4800bps, 9600bps

 

 

 

19.2kbps, 38.4kbps, 57.6kbps

 

BEACON

4800bps

 

DISABLE

-

 

Note: Underline shows default.

LONG RANGE: Long range communication device, for ex. Inmarsat C.

EXT DISPLAY: External display, for ex. Radar, ECDIS, Pilotplug, etc.

SENSOR: GPS, Gyrocompass, Speedlog, ROT, etc.

HI LEVEL IF: NAVNET 2

STANDARD (PC port): PC for inputting NMEA data (Same data as EXT DISPLAY).

MONITOR (PC port): PC having the FURUNO software FAISPC MK-2.

SERVICE (PC port): Service use FAISPC MK-2-equipped PC.

24

Image 30
Contents Uais Transponder 00015008314 Safety Instructions System Configuration Category of the unitsEquipment Lists Standard supplyIii Optional supply GPS antenna unit MountingAntenna Units Extending antenna cableHow to attach the connector N-P-8DFB for cable 8D-FB-CV How to attach connector N-P-8DFBVHF antenna Location CablingHorizontal separation distance How to attach the plug M-P-7 Installation overview of GPS/VHF combined antenna3 GPS/VHF combined antenna Mounting procedure GPS/VHF Combined antennaInstalling distributor unit DB-1 Monitor Unit Desktop mountingFlush mounting Type Name Type Code No QtyUais Transponder MountingPower Supply option Pilot Plug optionWiring ConnectionInternal ports of the Transponder Cable connection at transponder Fabrication of cables TTYCS-4, TTYCS-1Q and TTYCS-1How to attach wires to the Wago connector Fabrication of power cable DPYC-2.5Changing Ship’s Mains Specifications 100-115 VACSetting and Adjustment Inland AIS Specific SettingsEntering activation key Password entry window Selecting AIS modeSetting blue sign status NAV Status menu initial sub-menuInitial Settings menu SET Blue Sign SW sub-menuSetting MMSI, IMO No., Name and Call Sign SET Mmsi sub-menu Setting GPS Antenna Position Setting COM port/PC port Setting Ship TypeSetting I/O Port Table Ship typePress the ENT key again to display the Mode setting window COM1 Long Range Priority setup Priority menuQuality setup Inland AIS only Attaching LAN KIT Option AttachingSetting LAN port for PC network Setting LAN port for Navnet 3D networkContinuous This page intentionally left blank IEC 61162-1/2 Data Sentences TransponderInland AIS specific sentences Input data/SentencesOutput data/Sentences Input+056#..#6+10/#64+#.5 # 8# #%%5514+5 Antenna Cable Set CP20-02700 CP20-02710 Antenna Cable Set CP20-00300 CP20-00310 Page Page Page Hatai Mar,2707 R.Esumi May 20 Page Jan 26/Oct/09 R.Esumi Page Page Page Page Page Transponder Unit