How to attach the connector N-P-8DFB for cable 8D-FB-CV
Outer Sheath | Dimensions in millimeters. | |
Armor | Inner Sheath Shield | |
| 50 | 30 |
Cover with
Remove outer sheath and armor by the dimensions shown left.
Expose inner sheath and shield by the dimensions shown left.
Cut off insulator and core by 10mm.
30 | 10 |
Clamp | Gasket Clamp |
Nut | (reddish |
| brown) |
| Aluminum Foil |
Trim shield here.
Insulator
Trim aluminum tape foil here.
Twist shield end.
Slip on clamp nut, gasket and clamp as shown left.
Fold back shield over clamp and trim.
Cut aluminum foil at four places, 90° from one another.
Fold back aluminum foil onto shield and trim.
1
5
Pin
Clamp Nut
Shell
Solder through the hole.
Expose the insulator by 1mm.
Expose the core by 5mm.
Slip the pin onto the conductor. Solder them together through the hole on the pin.
Insert the pin into the shell. Screw the clamp nut into the shell.
(Tighten by turning the clamp nut. Do not tighten by turning the shell.)
How to attach connector N-P-8DFB
2