Furuno FA-150 installation manual 3 GPS/VHF combined antenna, How to attach the plug M-P-7

Page 11

How to attach the plug M-P-7

Lay the coaxial cable and attach an M-type plug (if necessary) to the cable as follows.

1.Remove the sheath by 30 mm.

2.Bare 23 mm of the center conductor. Trim braided shield by 5 mm and tin.

3.Slide coupling ring onto cable.

4.Screw the plug assembly on the cable.

5.Solder plug assembly to braided shield through solder holes. Solder contact sleeve to conductor.

6.Screw coupling ring into plug assembly.

Sheath

5 mm

Braided shield

Plug assembly

30 mm

2 mm

Conductor

Insulator

Contact sleeve

 

Solder both

Cut conductor here.

Coupling ring

 

sides of hole.

 

1.1.3 GPS/VHF combined antenna

Install the combined antenna unit referring to the outline drawing. When selecting a mounting location for the antenna, keep in mind the following points.

Select a location out of the radar beam. The radar beam will obstruct or prevent reception of the GPS satellite signal.

There should be no interfering object within the line-of-sight to the satellites. Objects within line-of-sight to a satellite, for example, a mast, may block reception or prolong acquisition time.

Mount the antenna unit as high as possible. Mounting it this way keeps it free of interfering objects and water spray, which can interrupt reception of GPS satellite signal if the water freezes.

Also, refer to the antenna installation guidelines page 3.

Outdoor Indoor

Distributor DB-1

GPS UAIS Transponder

N-P-8DFB

RG-10U/Y

VHF

N-P-8DFB

Installation overview of GPS/VHF combined antenna

5

Image 11
Contents Uais Transponder 00015008313 Safety Instructions Category of the units System ConfigurationIii Equipment ListsStandard supply Optional supply Extending antenna cable MountingAntenna Units GPS antenna unitHow to attach connector N-P-8DFB Cabling VHF antenna LocationHorizontal separation distance 3 GPS/VHF combined antenna How to attach the plug M-P-7Mounting procedure Installing distributor unit DB-1 Flush mounting Monitor UnitDesktop mounting Name Type Code No Qty TypeMounting Uais TransponderPilot Plug option Power Supply optionConnection WiringInternal ports of the Transponder Armor Connection Cable connection at transponderFabrication of cables TTYCS-4 and TTYCS-1Q Fabrication of power cable DPYC-2.5 200-230 VAC White Black 100-115 VAC Changing Ship’s Mains SpecificationsSetting MMSI, IMO No., Name and Call Sign Setting and AdjustmentSET Mmsi window Setting GPS Antenna Position Setting COM port/PC port Setting Ship TypeSetting I/O Port Press the ENT key again to display the Mode setting window Mode Speed Long Range Priority menu Priority setupAttaching Attaching LAN KIT OptionSetting LAN port for Navnet 3D network Setting LAN port for PC networkContinuous Transponder IEC 61162-1/2 Data SentencesOutput data/Sentences Input data/SentencesFor FA-1501 For GPA-017S/GSC-001 For DB-1 For FA-1502 Antenna Cable Set CP20-00300 CP20-00310 Page Page Page Hatai Mar,2707 R.Esumi May 20 Page Jan Apr.2007 R.Esumi Page Page Page Page Transponder Unit